npm package discovery and stats viewer.

Discover Tips

  • General search

    [free text search, go nuts!]

  • Package details

    pkg:[package-name]

  • User packages

    @[username]

Sponsor

Optimize Toolset

I’ve always been into building performant and accessible sites, but lately I’ve been taking it extremely seriously. So much so that I’ve been building a tool to help me optimize and monitor the sites that I build to make sure that I’m making an attempt to offer the best experience to those who visit them. If you’re into performant, accessible and SEO friendly sites, you might like it too! You can check it out at Optimize Toolset.

About

Hi, 👋, I’m Ryan Hefner  and I built this site for me, and you! The goal of this site was to provide an easy way for me to check the stats on my npm packages, both for prioritizing issues and updates, and to give me a little kick in the pants to keep up on stuff.

As I was building it, I realized that I was actually using the tool to build the tool, and figured I might as well put this out there and hopefully others will find it to be a fast and useful way to search and browse npm packages as I have.

If you’re interested in other things I’m working on, follow me on Twitter or check out the open source projects I’ve been publishing on GitHub.

I am also working on a Twitter bot for this site to tweet the most popular, newest, random packages from npm. Please follow that account now and it will start sending out packages soon–ish.

Open Software & Tools

This site wouldn’t be possible without the immense generosity and tireless efforts from the people who make contributions to the world and share their work via open source initiatives. Thank you 🙏

© 2024 – Pkg Stats / Ryan Hefner

windows-kill-napi

v0.3.4

Published

Sending signals on Windows OS

Downloads

53

Readme

node-windows-kill

NPM version Build Status Build status codecov Known Vulnerabilities GitHub license

Enhance node's process.kill to support signals in Windows

Installation

$ npm install windows-kill

Features

  • No code change is needed. Just old process.kill calls.
  • Support Both x86 & x64 Windows
  • No effect on Non Windows operation systems (Linux, Mac OS X, etc...)
  • Support both SIGINT and SIGBREAK (Just the two signals that are available on Windows)

Why windows-kill?

Sending signal to another process, just by knowing it's PID, is not available at Windows OS. It's a POSIX OSes feature. But, sending signal to other process, for telling it that something is going to happen to you, is a way to give other process some time for graceful shutdown/restart. windows-kill tries to fix this issue by bringing the ability to send signals, SIGINT and SIGBREAK, to another process by PID.

How it works?

To read a detailed info please visit windows-kill-library Readme.

Limitations

To send the signal, windows-kill at first send a same signal to the process that is calling it, to find a thread address. Then the founded address is used to send the real signal. Because of this, the process that is sending the signal will get the same signal too. But windows-kill register a signal handle during this procedure, so the process will not terminate. But if the process that is sending signal has child process, or is a child process of another process, sending signal will trigger the signal handles in other process in the same process group. And the default behavior of Windows console/application in case of getting a SIGINT or SIGBREAK, is to terminate.

sum up: If you are sending signal in node app that has child process (any kind of it), or is a child process of another process, the result is the termination of all the processes in the same process group, except the sender (well if it's a child process, because the master is terminated, it will terminate too).

PS: ~~Currently there is no solution for this problem. But I'm working on it, to find a solution.~~ Solutions for different scenarios added.

PS-1: ~~A solution for parent processes that wants to send signal (no way for child processes currently), is added. It's setting the warmUp: true option when first calling the windows-kill in parent, before any child processes creation.~~

Usage

windows-kill expose a function. Simply run the exposed function with/without the options. Thats it. It should be called before any usage of process.kill.

By default, windows-kill will enhance the node's process.kill in a way, that no code changes are needed in your codebase. Enhance means that windows-kill will replace the node's process.kill with a custom function with the same arguments and functionality. Just some changes to achieve signaling in Windows.

Simplest usage

The returned function from calling the exported function, could be used to send signal, just like the way you call process.kill. It will accept two argument. a PID and a SIGNAL.

/*
    Require and call the function that's exported.
    The returned function can be used to send signal.
*/
var windowsKill = require('windows-kill')();

/*
    By default, process.kill is enhanced (only in Windows OS),
    so you can either call process.kill, or the returned function.
*/
process.kill(PID, SIGNAL);
windowsKill(PID, SIGNAL);
/*
    Just call the function, and no need to change any code.
    Every process.kill calls in your code, will now enhanced.
    Just need to call windows-kill, before any call of
    process.kill.
*/
require('windows-kill')();

process.kill(PID, SIGNAL);

Options

Options and default values are:

const defaultOptions = {
    replaceNodeKill: true,
    warmUp: false
};

replaceNodeKill

This option will tell the windows-kill that should it enhance/replace the nodes process.kill? By setting true (default value), the nodes process.kill will replaced by a custom function. This custom function will check the signal that is sending using process.kill. If the signal is a member of supported signals, which is SIGINT or SIGBREAK, it will call the modules function that is responsible for sending signal. Otherwise, the signal and pid will be passed to the node's original process.kill.

const options = {
    replaceNodeKill: true, // Should windows-kill enhance/replace node's process.kill? Default: true
};

require('windows-kill')(options);

process.kill(PID, SIGNAL);
const options = {
    replaceNodeKill: false // Should windows kill enhance/replace node's process.kill. Default: true
};

var windowsKill = require('windows-kill')(options);

windowsKill(PID, SIGNAL);

warmUp

By setting warmUp to true, windows-kill will find and save the ctrl-routine addresses, without any need to send signal. By default, the address will find, when the first signal of that type is sending. Future call will use the founded address.

const options = {
    warmUp: true, // Should windows-kill warm-up by finding the ctrl-routines addresses? Default: false
};

require('windows-kill')(options);

process.kill(PID, SIGNAL);

Warm-up, is one way to overcome the limitations. Setting this option, will make the windows-kill to find needed address, before any signal sending. As stated in limitations section, finding address will cause the processes that have child process, or is a child process, trigger the ctr-routine of all process group members, which means termination of all of them. But warm-up mechanism can be used, to fix the issue in parent process. By setting it to true, before any child process creation, sending signal in future will use the save addresses and no need to find addresses again.

Parent process only send signal
var options = {
    warmUp: false
};

var cp = require('child_process');
var windowsKill = require('windows-kill')(options);

var cp1 = cp.spawn('node', ['cp.js']);

windowsKill(PID, 'SIGINT');

By running the above code, the cp1 child process will terminate. Because the SIGINT signal is sent for the first time, and the ctrl-routine address in not available. So windows-kill will try to find it, and trying to find it will trigger the SIGINT handler of cp1 child process, which lead to termination of cp1.

To solve the issue, we can set the warmUp option true. Just remember, the initialization of windows-kill with warmUp option should be done before any child process creation. Like below:

var options = {
    warmUp: true
};

var cp = require('child_process');
var windowsKill = require('windows-kill')(options);

var cp1 = cp.spawn('node', ['cp.js']);

windowsKill(PID, 'SIGINT');
Cluster master only send signal

To avoid the termination of child processes (forks), you should use warmUp option in the master creation part.

var cluster = require('cluster');
var os = require('os');

if (cluster.isMaster) {
    /*
        Initialize windows-kill here. Before and child process creation,
        just in the master process code.
    */
    var windowsKill = require('windows-kill')({
        "warmUp": true
    });

    for (let i = 0; i < os.cpus().length; i++) {
        cluster.fork();
    }
} else {
    /* Child Process code, that is not using windows-kill*/
}

Contributing

We love contributions from everyone. Please read Contributing guide.

License

MIT