simple-mcp3008
v3.0.1
Published
MCP3008 SPI analog to digital conversion
Downloads
3
Readme
simple-mcp3008
MCP 3008 SPI analog to digital conversion with Node.js on raspberry boards.
Contents
Installation
npm install simple-mcp3008
Usage
// (SPICLK, SPIMISO, SPIMOSI, SPICS, Voltage)
var mcp = require('simple-mcp3008')(18,24,4,25,3.3);
for(var i = 0; i < 8; i++){
console.log("pin #" + i + " = " + mcp.pins[i].getDecimalValue() + "/1024");
}
var mcp = require('simple-mcp3008')(18,24,4,25,3.3);
var temp_pin = mcp.pins[0];
/* MJSTS-103-3950-1-600-3D [celcius degre, ohm]*/
var temp_sensor_resistances = [[-30, 173755],[-29, 163652.4],[-20, 97420.46],[-10, 55801.49],[0, 32997.68],[10, 20068.96],[20, 12513.07],[30, 8070.342],[40, 5320.219],[50, 3583.472],[60, 2490.09]];
console.log("pin value = " + temp_pin.getDecimalValue() + "/1024");
console.log("pin #0 voltage = " + temp_pin.getVoltage());
console.log("Define type + constant resistance to pin 0");
temp_pin.setType("temp");
temp_pin.setConstantResistance(10000 - 5000);
console.log("constant resistance = " + temp_pin.resistance);
console.log("New voltage = " + temp_pin.getVoltage() + " V");
console.log("Sensor resistance = " + temp_pin.getSensorResistance() + " Ohm");
temp_pin.setResistanceTab(temp_sensor_resistances);
console.log("temp = " + temp_pin.getCelciusDegre() + " °C");