npm package discovery and stats viewer.

Discover Tips

  • General search

    [free text search, go nuts!]

  • Package details

    pkg:[package-name]

  • User packages

    @[username]

Sponsor

Optimize Toolset

I’ve always been into building performant and accessible sites, but lately I’ve been taking it extremely seriously. So much so that I’ve been building a tool to help me optimize and monitor the sites that I build to make sure that I’m making an attempt to offer the best experience to those who visit them. If you’re into performant, accessible and SEO friendly sites, you might like it too! You can check it out at Optimize Toolset.

About

Hi, 👋, I’m Ryan Hefner  and I built this site for me, and you! The goal of this site was to provide an easy way for me to check the stats on my npm packages, both for prioritizing issues and updates, and to give me a little kick in the pants to keep up on stuff.

As I was building it, I realized that I was actually using the tool to build the tool, and figured I might as well put this out there and hopefully others will find it to be a fast and useful way to search and browse npm packages as I have.

If you’re interested in other things I’m working on, follow me on Twitter or check out the open source projects I’ve been publishing on GitHub.

I am also working on a Twitter bot for this site to tweet the most popular, newest, random packages from npm. Please follow that account now and it will start sending out packages soon–ish.

Open Software & Tools

This site wouldn’t be possible without the immense generosity and tireless efforts from the people who make contributions to the world and share their work via open source initiatives. Thank you 🙏

© 2024 – Pkg Stats / Ryan Hefner

s7reader

v1.0.1

Published

This packages polls data from siemens s7 plcs and publishes it over the mqtt network.

Downloads

1

Readme

S7Reader

s7reader is a library that allows communication to S7-300/400/1200/1500 PLCs using the Siemens S7 Ethernet protocol RFC1006.

This software is not affiliated with Siemens in any way, nor am I. S7-300, S7-400, S7-1200 and S7-1500 are trademarks of Siemens AG.

WARNING

Fully test everything you do. In situations where writing to a random area of memory within the PLC could cost you money, back up your data and test this really well. If this could injure someone or worse, consider other software.

Installation

Using npm:

  • npm install s7reader

Using yarn:

  • yarn add s7reader

Optimization

  • It is optimized in three ways - It sorts a large number of items being requested from the PLC and decides what overall data areas to request, then it groups multiple small requests together in a single packet or number of packets up to the maximum length the PLC supports, then it sends multiple packets at once, for maximum speed. So a request for 100 different bits, all close (but not necessarily completely contiguous) will be grouped in one single request to the PLC, with no additional direction from the user.

  • s7reader manages reconnects for you. So if the connection is lost because the PLC is powered down or disconnected, you can continue to request data with no other action necessary. "Bad" values are returned, and eventually the connection will be automatically restored.

  • s7reader is written entirely in Javascript, so no compiler installation is necessary on Windows, and deployment on other platforms (ARM, etc) should be no problem.

PLC Support

  • S7-1200 and S7-1500 CPU access requires access using "Slot 1" and you must disable optimized block access (in TIA portal) for the blocks you are using. In addition, you must "Enable GET/PUT Access" in the 1200/1500 controller in TIA Portal. Doing so opens up the controller for other access by other applications as well, so be aware of the security implications of doing this.

  • This has been tested on direct connections to newer PROFINET CPUs and Helmholz NetLINK PRO COMPACT and IBH units. (Note with these gateways you often have to specify the MPI address as the slot number) It is reported to work with other CPU/CP combinations as well, although not all S7-200 datatypes are supported. S7 routing is not supported.

  • Logo 0BA8 PLCs are supported although you should set your local and remote TSAP to match your project, and your addresses have to be specified differently. DB1,INT0 should get VM0. DB1,INT1118 should get AM1.

VFD Support

  • SINAMICS S120 and G120 FW 4.7 and up work as well, as these drives support direct connection USING SLOT 0 (instead of other examples that use 1 or 2) and some modified parameter addressing. This technique can work with these drives with other software as well and is documented on the Siemens website. Basically, to address parameter number 24, output frequency for example, is defined in the documentation as a real number, so DB24,REAL0 would return the output frequency. If this parameter were an array, DB24,REAL1 would return the next in sequence even though a Siemens programmer would be tempted to use REAL4 which is not correct in this case. For this reason, normal S7 optimization must be disabled. After you declare conn = new s7reader; (or similar) then add conn.doNotOptimize = true; to ensure this isn't done, and don't try to request these items using array notation as this implies optimization, request REAL0 then REAL1 etc. doNotOptimize is now also supported as a connection parameter.

Credit to the S7 Wireshark dissector plugin for help understanding why things were not working. (http://sourceforge.net/projects/s7commwireshark/)

Examples

var s7reader = require('s7reader'); // This is the package name, if the repository is cloned you may need to require 's7reader' with uppercase S
var conn = new s7reader;
var doneReading = false;
var doneWriting = false;

var variables = {
      TEST1: 'MR4',          // Memory real at MD4
      TEST2: 'M32.2',        // Bit at M32.2
      TEST3: 'M20.0',        // Bit at M20.0
      TEST4: 'DB1,REAL0.20', // Array of 20 values in DB1
      TEST5: 'DB1,REAL4',    // Single real value
      TEST6: 'DB1,REAL8',    // Another single real value
      TEST7: 'DB1,INT12.2',  // Two integer value array
      TEST8: 'DB1,LREAL4',   // Single 8-byte real value
      TEST9: 'DB1,X14.0',    // Single bit in a data block
      TEST10: 'DB1,X14.0.8'  // Array of 8 bits in a data block
};

conn.initiateConnection({ port: 102, host: '192.168.0.2', rack: 0, slot: 1, debug: false }, connected); // slot 2 for 300/400, slot 1 for 1200/1500, change debug to true to get more info
// conn.initiateConnection({port: 102, host: '192.168.0.2', localTSAP: 0x0100, remoteTSAP: 0x0200, timeout: 8000, doNotOptimize: true}, connected);
// local and remote TSAP can also be directly specified instead. The timeout option specifies the TCP timeout.

function connected(err) {
  if (typeof(err) !== "undefined") {
    // We have an error. Maybe the PLC is not reachable.
    console.log(err);
    process.exit();
  }
  conn.setTranslationCB(function(tag) { return variables[tag]; }); // This sets the "translation" to allow us to work with object names
  conn.addItems(['TEST1', 'TEST4']);
  conn.addItems('TEST6');
  // conn.removeItems(['TEST2', 'TEST3']); // We could do this.
  // conn.writeItems(['TEST5', 'TEST6'], [ 867.5309, 9 ], valuesWritten); // You can write an array of items as well.
  // conn.writeItems('TEST7', [666, 777], valuesWritten); // You can write a single array item too.
  conn.writeItems('TEST3', true, valuesWritten); // This writes a single boolean item (one bit) to true
  conn.readAllItems(valuesReady);
}

function valuesReady(anythingBad, values) {
  if (anythingBad) { console.log("SOMETHING WENT WRONG READING VALUES!!!!"); }
  console.log(values);
  doneReading = true;
  if (doneWriting) { process.exit(); }
}

function valuesWritten(anythingBad) {
  if (anythingBad) { console.log("SOMETHING WENT WRONG WRITING VALUES!!!!"); }
  console.log("Done writing.");
  doneWriting = true;
  if (doneReading) { process.exit(); }
}

API

s7reader.initiateConnection(options, callback)

Description

Connects to a PLC.

Arguments

Options

|Property|type|default| | --- | --- | --- | | rack | number | 0 | | slot | number | 2 | | port | number | 102 | | host | string | 192.168.8.106 | | timeout | number | 5000 | | localTSAP | hex | undefined | | remoteTSAP | hex | undefined |

callback(err)

s7reader.dropConnection(callback)

Description

Disconnects from a PLC. This simply terminates the TCP connection.

Arguments

callback()

The callback is called upon completion of the close.

s7reader.setTranslationCB(translator)

Description

Sets a callback for name - address translation.

This is optional - you can choose to use "addItem" etc with absolute addresses.

If you use it, translator should be a function that takes a string as an argument, and returns a string in the following format: <data block number.><memory area><data type><byte offset><.array length>

Examples:

  • MR30 - MD30 as REAL
  • DB10,LR32 - LREAL at byte offset 32 in DB10, for 1200/1500 only
  • DB10,INT6 - DB10.DBW6 as INT
  • DB10,I6 -same as above
  • DB10,INT6.2 - DB10.DBW6 and DB10.DBW8 in an array with length 2
  • DB10,X14.0 - DB10.DBX14.0 as BOOL
  • DB10,X14.0.8 - DB10.DBB14 as an array of 8 BOOL
  • PIW30 - PIW30 as INT
  • DB10,S20.30 - String at offset 20 with length of 30 (actual array length 32 due to format of String type, length byte will be read/written)
  • DB10,S20.30.3 - Array of 3 strings at offset 20, each with length of 30 (actual array length 32 due to format of String type, length byte will be read/written)
  • DB10,C22.30 - Character array at offset 22 with length of 30 (best to not use this with strings as length byte is ignored)
  • DB10,DT0 - Date and time
  • DB10,DTZ0 - Date and time in UTC
  • DB10,DTL0 - DTL in newer PLCs
  • DB10,DTLZ0 - DTL in newer PLCs in UTC

The DT type is the well-known DATE_AND_TIME type of S7-300/400 PLCs, a 8-byte-wide field with BCD-encoded parts

The DTZ type is the same as the DT, but it expects that the timestamp is in UTC in the PLC (usually NOT the case)

The DTL type is the one seen on newer S7-1200/1500 PLCs, is 12-byte long and encodes the timestamp differently than the older DATE_AND_TIME

The DTLZ type is also the same as the DTL, but expecting the timestamp in UTC in the PLC

In the example above, an object is declared and the translator references that object. It could just as reference a file or database. In any case, it allows cleaner Javascript code to be written that refers to a name instead of an absolute address.

s7reader.addItems(items)

Description

Adds items to the internal read polling list.

Arguments

items can be a string or an array of strings.

If items includes the value _COMMERR it will return current communication status.

s7reader.removeItems(items)

Description

Removes items to the internal read polling list.

Arguments

items can be a string or an array of strings.

If items is not defined then all items are removed.

s7reader.writeItems(items, values, callback)

Description

Writes items to the PLC using the corresponding values and calls callback when done.

You should monitor the return value - if it is non-zero, the write will not be processed as there is already one it progress, and the callback will not be called.

Arguments

items can be a string or an array of strings.

If items is a single string, values should then be a single item.

If items is an array of strings, values must also be an array of values.

callback(err)

s7reader.readAllItems(callback)

Description

Reads the internal polling list and calls callback when done.

Arguments

callback(err, values)