node-threshold-control
v0.0.8
Published
Treshold control
Downloads
51
Maintainers
Readme
Threshold control
With the treshold control you can enable or disable a delayed output when the input passes the on or off threshold.
Configuration
There are a few values that need configuration before the node can be used:
- On payload - The
msg.payload
to send when the on threshold get passed (and the counter reaches zero). - Off payload - The
msg.payload
to send when the off threshold get passed (and the counter reaches zero). - On threshold - As soon as this threshold gets passed by
msg.payload
, the onDelay counter counts down to zero. If that hass passed, a "on"msg.payload
gets send to the first output._ - Off threshold - As soon as this threshold gets passed by
msg.payload
, the offDelay counter counts down to zero. If that hass passed, a "off"msg.payload
gets send to the first output. - On delay - the delay in seconds that is waited before the output gets send after the input passes the on threshold.
- Off delay - the delay in seconds that is waited before the output gets send after the input passes the off threshold.
The on threshold should be higher than the off threshold.
Note that the delay is in whole seconds. It rounds it to the nearest integer when input is not in whole seconds.
Input
By default the node listens to msg.payload
as input.
It also listens to different messages, which can change the configured values:
msg.onThreshold
- The on thresholdmsg.offThreshold
- The off thresholdmsg.onDelay
- The on delay in secondsmsg.offDelay
- The off delay in seconds
Outputs
There are three outputs. The first one just gives "on" or "off" (after the delay has passed).
The second output gives the state of the counter for the on delay.
The third output gives the state of the couter for the off delay.
Both second and third outputs also publish a msg.blink
that is 0
or 1
when the counter is even or odd.
Status
The status node tries to show the current state. It can turn red on wrong input and on the "off" state, green on the "on" state and yellow when the on or off counter is running.
When you do a fresh deploy and then inject values within the hysteresis region (between on and off thresholds) the Node status will be displayed as "unknown" with a blue dot.