node-red-contrib-knx-ultimate-plus-hue-contact-sensor
v2.5.5
Published
This is a fork of node-red-contrib-knx-ultimate. Thanks to the original author! Control your KNX installation via Node-Red! A bunch of KNX nodes, with integrated Philips HUE control and ETS group address importer. Easy to use and highly configurable.
Downloads
108
Maintainers
Readme
Control your KNX intallation via Node-Red! A bunch of KNX nodes, with integrated Philips HUE control and ETS group address importer. Easy to use and highly configurable.
You can use it immediately!
msg.payload = true // Turn light on
msg.payload = {red:255, green:200, blue:30} // Put some colors in our life
NODE LIST
- KNX-ULTIMATE node here, allow you to control your KNX installation via Node-Red. You can control all your KNX devices as well as create a Virtual Device in Node-Red, to link external non KNX devices, and make it compatible with your KNX installation. I'ts very SIMPLE TO USE thus very customizable.
- SCENE CONTROLLER node here, The scene controller node can act as a real scene controller, with recall and save of the current scene.
- WATCHDOG node here, allows notification (Email, Twitter, Telegram, Alexa, Siri, Sonos -with sonospollytts node- and so on) of KNX Bus connection errors, automatic or manual switchover to a backup KNX/IP router if the primary fails and allows you to programmatically change the config-node directly from a msg flow. It also can force the disconnection and connection of the selected Gateway from the KNX BUS.
- LOGGER node here, creates an XML diagnostic file, compatible with ETS. You can open it with ETS for diagnostic pourposes. Node: the Logger currently doesn't record the telegrams coming from KNX-Ultimate if you use a KNX/IP Interface.
- GLOBAL CONTEXT node here, exposes the group addresses to a Global Context variable, to be used in function nodes.
- ALERTER node here. With the Alerter node you can signal to a display or to the node-red-contrib-tts-ultimate node (audio feedback), whenever the selected devices are alerted, i.e. they have payload true.
- LOAD CONTROL node here. Control your loads (Oven, Washing machine, etc..) and avoit shutting down the main voltage due to too high power consumption.
- VIEWER node here. View all Group Addresses and values of your KNX BUS, in the Node-Red Dashboard.
- PHILIPS HUE nodeset here. Link HUE devices to KNX in a simple way.
CHANGELOG
- See here the changelog
VOLUNTEER NEEDED FOR KNX SECURE
KNX-Secure is under development. I need volunteer helping in development of KNX Secure. High knowledge of cryptography and KNX is needed.
HELP, SAMPLES, TROUBLESHOOT, WIKI, FAQ, BEST PRACTICES
Tons of documentation, samples, even for use in conjunction with
STARTER PACK
Highlights
If you're here, you probably already have tried other knx nodes from npm. I hope you enjoy this one, because i've put big effort to do what i really needed, a copy/paste friendly node, with many functions and the possibility to use the ETS csv exported Group Addresses.
You can set you own group address, datapoint and device name, or you can import the ETS Group Address list and have datapoint and device name auto populated while typing in the group address.
If you import your ETS CSV or ESF file, just begin typing the group address or the device name in the Group Address textbox and a list of possible matches will appear. Just select an item in the list it and have datapoint and device name auto populated. You can then accept the auto populated fields or change it.
Just pass a normal payload to the node (true, false, a string or any nymber) and just receive a normal payload (true, false, a string or any nymber) to use in your flow.
The node can act as a single device (for example having Group Address 0/0/1), or can be used as universal node, catching all messages coming from KNX Bus (in this case the node will output a comprehensive msg to the flow, containing group address, device name, automatic decoded payload and other useful infos). The node can act as universal KNX sender as well (you can pass a message to the node, containing the destination group address, the datapont type and the payload).
There is samples. There is huge documentation about settings and properties. If this is not enough for you, whenever you change the datapoint type, a textblock with a sample msg input (expecially, for tricky datapoints, like RGBW, 10Bytes, Relative Dimming, 3 Bytes setpoint etc...) appears. Just copy/paste it in a function and you're done.
It supports a huge amount of datapoints. If you need more, just open a GitHub issue.
The Node protects you, from mistakes you can do. Node Protections
You can select to activate or deactivate it. If active, the node reacts only if payload from KNX Bus or from input msg is changed.
Full support for IP Interfaces as well for IP Routers. It's recommended the use of IP Routers because of simple setup and stability in a large environment.
You can send RAW buffers directly to the bus.
WORKING WITH THE ETS CSV FILE OR WITH ESF FILE
Instead of create a knx-ultimate node for each Group Address to control, you can import your ETS csv or esf group addresses file.
Thanks to that, the knx-ultimate node where you selected Universal mode (listen to all Group Addresses), becomes an universal input/output node, aware of all Datapoints, Group Addresses and Device's name (ex: Living Room Lamp). Just send the payload to the knx-ultimate node, and it'll encode it with the right datapoint and send it to the bus. Likewise, when the knx-ultimate node receives a telegram from the bus, it outputs a right decoded payload using the datapoint specified in the ETS file.
Copy/Paste this into your configuration node.
"Group name" "Address" "Central" "Unfiltered" "Description" "DatapointType" "Security"
"Attuatori luci" "0/-/-" "" "" "Attuatori luci" "" "Auto"
"Luci primo piano" "0/0/-" "" "" "Luci primo piano" "" "Auto"
"Camera da letto luce" "0/0/1" "" "" "Camera da letto luce" "DPST-1-8" "Auto"
"Loggia camera da letto" "0/0/2" "" "" "Loggia camera da letto" "DPST-1-1" "Auto"
"Camera armadi luce" "0/0/3" "" "" "Camera armadi luce" "DPST-1-1" "Auto"
"Bagno grande luce" "0/0/4" "" "" "Bagno grande luce" "DPST-1-1" "Auto"
"Loggia bagno grande" "0/0/5" "" "" "Loggia bagno grande" "DPST-1-1" "Auto"
"Bagno grande specchio (switch)" "0/0/6" "" "" "Bagno grande specchio switch" "DPST-1-1" "Auto"
"Lavanderia luce" "0/0/7" "" "" "Lavanderia luce" "DPST-1-1" "Auto"
"Lavanderia specchio (switch)" "0/0/8" "" "" "Lavanderia specchio switch" "DPST-1-1" "Auto"
"Studio luce" "0/0/9" "" "" "Studio luce" "DPST-1-1" "Auto"
"Soggiorno luce (switch)" "0/0/10" "" "" "Soggiorno luce switch" "DPST-1-1" "Auto"
"Soggiorno aplique (switch)" "0/0/11" "" "" "Soggiorno aplique switch" "DPST-1-1" "Auto"
"Loggia soggiorno cucina" "0/0/12" "" "" "Loggia soggiorno-cucina" "DPST-1-1" "Auto"
"Cucina luce" "0/0/13" "" "" "Cucina luce" "DPT-1" "Auto"
"Cucina luce pensili" "0/0/14" "" "" "Cucina luce pensili" "DPT-1" "Auto"
"Corridoio luce" "0/0/15" "" "" "Corridoio luce" "DPST-1-1" "Auto"
"Scala LED" "0/0/16" "" "" "Scala LED" "DPST-1-1" "Auto"
"Soggiorno aplique brighness value" "0/0/17" "" "" "" "DPST-5-1" "Auto"
"Bagno grande specchio (dim)" "0/0/18" "" "" "Bagno grande specchio dim" "DPST-3-7" "Auto"
"Soggiorno luce brighness value" "0/0/19" "" "" "" "DPST-5-1" "Auto"
"Lavanderia specchio (dim)" "0/0/20" "" "" "Lavanderia specchio dim" "DPST-3-7" "Auto"
"Scala LED cambiacolori RGB" "0/0/21" "" "" "" "DPST-1-1" "Auto"
"Bagno grande specchio brightness value" "0/0/22" "" "" "" "DPST-5-1" "Auto"
"Soggiorno luce (dim)" "0/0/23" "" "" "Soggiorno luce dim" "DPST-3-7" "Auto"
Copy/Paste this into your configuration node.
My beautiful home
Attuatori luci.Luci primo piano.0/0/1 Luce camera da letto EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/2 Luce loggia camera da letto EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/3 Luce camera armadi EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/4 Luce bagno grande EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/5 Luce loggia bagno grande EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/6 Luce specchio bagno grande (switch) EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/7 Luce lavanderia EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/8 Luce specchio lavanderia (switch) EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/9 Luce studio EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/10 Plafoniera soggiorno (switch) EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/11 Applique soggiorno (switch) EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/12 Luce loggia soggiorno cucina EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/13 Luce cucina EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/14 Pensili cucina EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/15 Luce corridoio EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/16 LED scala EIS 1 'Switching' (1 Bit) Low
Attuatori luci.Luci primo piano.0/0/18 Luce specchio bagno grande(dim) EIS 2 'Dimming - control' (4 Bit) Low
Attuatori luci.Luci primo piano.0/0/20 Luce specchio lavanderia (dim) EIS 2 'Dimming - control' (4 Bit) Low
Attuatori luci.Luci primo piano.0/0/23 Plafoniera soggiorno (dim) EIS 2 'Dimming - control' (4 Bit) Low
Attuatori luci.Luci primo piano.0/0/24 Applique soggiorno (dim) EIS 2 'Dimming - control' (4 Bit) Low
Attuatori luci.Luci primo piano.0/0/17 Applique soggiorno brighness value Uncertain (1 Byte) Low
Attuatori luci.Luci primo piano.0/0/19 Plafoniera soggiorno brighness value Uncertain (1 Byte) Low
Attuatori luci.Luci primo piano.0/0/21 LED cambiacolori RGB scala EIS 1 'Switching' (1 Bit) Low
You can work with a mix of knx-ultimate nodes, some with Universal mode (listen to all Group Addresses) checked and some not. You are absolutely free! See this youtube video,
Click here for comprehensive samples
Turn on/off a Lamp
return {payload:true}
return {payload:false}
Increase the light/open blind
// The parameter "data" indicates the relative amount of the dimming commmand (how much to dim).
// The parameter "data" can be any integer value from 0 to 7
// The parameter decr_incr:1 increases the light
// The parameter decr_incr:0 decreases the light
msg.payload = {decr_incr: 1, data: 5};
return msg;
Set RGBW color
// Each color in a range between 0 and 255
msg.payload = {red:90, green:200, blue:30, white:120, mR:1, mG:1, mB:1, mW:1};
return msg;
--> MORE Samples and documentation....
COMMERCIAL COMPANIES USING KNX-ULTIMATE
List of commercial companies, which have given us permission to be mentioned on this page. Want to be listed here? Email to [email protected]
- Tervis - Alarm System Manufacturer
- KNX Sardegna - Gianmarco Sitzia, Certified KNX Partner
- Agata Store - Professional store and Certified KNX Partner
- ProKNX - KNX Device Manufacturer
- Altis - Energy and utilities provider
- Can'nX France - KNX Device Manufacturer and integrator
FRIENDLY COMMUNITIES AROUND THE WORLD
Italy
Germany
China
ARE YOU A NODEJS DEV? DO YOU KNOW THERE IS AN API FOR NODEJS?
Many users requested me to "extract" the baseline KNX API and make it accessible via npmjs. Here is it. The API is named KNXUltimate. In the README page is well documented and there are also samples for unsecure and secure KNX connections.
- KNXUltimate API
A big THANK YOU to @svenflender for the logo and icon graphics!