iobroker.hm-rega
v5.1.0
Published
Connects HomeMatic CCU "Logic Layer" ("ReGaHSS") to ioBroker
Downloads
4,341
Readme
ioBroker HomeMatic ReGaHSS Adapter
Connects HomeMatic CCU "Logic Layer" ("ReGaHSS") to ioBroker.
This adapter uses Sentry libraries to automatically report exceptions and code errors to the developers. For more details and for information how to disable the error reporting see Sentry-Plugin Documentation! Sentry reporting is used starting with js-controller 3.0.
Purpose
This Adapter keeps the HomeMatic CCU variables in sync with ioBroker and provides the possibility to start HomeMatic CCU programs from within ioBroker. Furthermore, this adapter can be used as a "migration helper": you can sync device/channel names, rooms, functions, and favorites from the CCU to ioBroker (this is one way only, changes in ioBroker will be overwritten once synced again – so deactivate this features after the first sync).
Install
This adapter requires one (ore more) already installed and initialized hm-rpc adapter(s) to work.
Configuration
FAQ
What are the ALARM states created in the devices object?
States which end on '_ALARM' are created by the Rega adapter, to represent service messages. The alarm has three
different states NO ALARM, which indicates that there is no related alarm (service message) for the state.
When a service message appears for the related state the state will change to ALARM, containing the timestamp
of the alarm occurrence on the CCU in the last changed timestamp of the state (state.ls). When you change
the state in ioBroker, this will acknowledge the alarm in the CCU and the service message will be gone.
The alarm state in ioBroker will change to ACKNOWLEDGED still containing the occurrence timestamp
in the last changed state, and the timestamp when it has been acknowledged in the state's timestamp (state.ts
).
I have a HomeMatic CCU2/CCU3, how can I add it to the adapter settings?
Within the adapter settings, you added the IP address of your CCU2, then
- Activate "rfd" for regular HomeMatic devices,
- Activate "HomeMatic IP" if you use HomeMatic IP devices,
- Activate "Virtual Devices" if you use Groups in HomeMatic (so if you combine e.g., multiple thermostats to a group)
If I modify rooms, etc. in HomeMatic, the changes are not applied right away within ioBroker.
Please reload the hm-rega adapter instance, e.g., by clicking on the reload icon of hm-rega.x (actions table) in the Instances tab.
Afterward, wait about 10-20 seconds and then check both the Enums tab and the Objects (enum.xxx
- make sure you enabled the expert mode). If the changes do still not appear, restart ioBroker. Then the changes should be available in ioBroker.
How can I sync the hidden/invisible variables, e.g., of HMIP-PSM?
Since version 2.4.0, it is possible to sync hidden variables. For this purpose, you have to go to the settings of hm-rega.
At the Sync tab you will find Invisible variables
when Variables
is checked.
I want to execute my own scripts on the CCU via ioBroker. Is this possible?
Since version 2.3.0 it is possible to execute your own scripts on the CCU by using the sendTo
command.
E.g., getting the uptime of your CCU by the following script:
My CCU webinterface has a different port than the standard http/https protocols, thus no connection is established. How can I configure the adapter to use a custom port for the webinterface?
Until now, this is an edge case and thus no configuration in the Admin GUI is possible. This has been decided because it would confuse 10,000 users to help one user. However, the port can still be changed via the cli, using the following command:
iob set hm-rega.0 --webinterfacePort 8765
To use default port settings again, either set 443/80
according to your protocol, or set 0
for automatic selection.
const upTimeScript = `
string stderr;
string stdout;
system.Exec("cat /proc/uptime | awk '// { printf $1/3600 }'", &stdout, &stderr);
WriteLine(stdout);`;
sendTo('hm-rega.0', upTimeScript, res => {
log(JSON.stringify(res), 'info');
});
My Rega API is running at another port than 8181 (HTTPS: 48181), can I use the adapter anyway?
If your Rega API is running at a non-default port (which should only happen in edge cases), we assume that you are familiar
with the ioBroker CLI. You can change the port via iob set hm-rega.<instance> --homematicPort <port>
Changelog
5.1.0 (2024-08-29)
- (@foxriver76) added notification if devices are low on battery
5.0.0 (2024-07-18)
- (bluefox) required node 18
- (bluefox) updated dependencies
4.0.0 (2023-09-04)
- (mcm1957) required node 16 due to adapter-core 3.x.x
- (bluefox) removed deprecated package -
request
3.0.47 (2023-08-08)
- (bluefox) Updated packages
3.0.46 (2023-03-30)
- (foxriver76) fixed for controller v5 (closes #368)
3.0.44 (2023-02-20)
- (foxriver76) compatibility of RSSI_DEVICE and RSSI_PEER for CCU updated (closes #352)
- (foxriver76) also sync enums for a maintenance channel of rfd devices (closes #320)
3.0.43 (2022-07-28)
- (foxriver76) if LGW is not reachable we now set duty cycle to
null
instead of-1
in all cases (closes #298)
3.0.40 (2022-04-03)
- (foxriver76) if LGW is not reachable we now set duty cycle to
null
instead of-1
3.0.39 (2022-03-26)
- (foxriver76) fixed another
ValueList
bug
3.0.38 (2022-03-26)
- (foxriver76) fixed bug with
ValueList
(closes #268)
3.0.37 (2022-02-22)
- (foxriver76) only delete hm-rpc objects of configured instances from enums (fixes #253)
3.0.35 (2022-01-28)
- (foxriver76) do not log warning if we cannot synchronize favorites of empty string user (fixes #227)
3.0.34 (2022-01-24)
- (martin-herzog/foxriver76) fixed unneeded call which lead to warnings in rega log
3.0.33 (2021-11-18)
- (foxriver76) if function or room names on CCU include dots, we replace them (fixes Sentry IOBROKER-HM-REGA-3H)
3.0.32 (2021-10-14)
- (foxriver76) Duty Cycle of LAN gateways can be -1 if they are disconnected (fixes #196)
- (foxriver76) we now only scale on UNIT "100%" as hm-rpc does (fixes #207)
3.0.31 (2021-08-12)
- (foxriver76) we fixed some sentry issues (closes #182, closes #183)
3.0.30 (2021-07-18)
- (foxriver76) improved the detection of ALARM occurrences for virtual devices
3.0.29 (2021-07-01)
- (foxriver76) fixed bug on ALARM datapoint creation
3.0.28 (2021-06-30)
- (foxriver76) improve creation of ALARM dps even if no states provided by
getDatapoints
(fixes #168)
3.0.27 (2021-06-28)
- (foxriver76) fixed a bug that already deleted programs were only partially deleted in ioBroker Please note: This will only work for deleted programs up from now. You have to clean up orphan programs manually
3.0.26 (2021-06-14)
- (bluefox) Use name from device if channel has a default name
3.0.25 (2021-05-14)
- (foxriver76) remove old code, which also scaled unit: % values and not only unit: 100 %
3.0.24 (2021-04-30)
- (foxriver76) we fixed more occurrences of incorrect types (fixes #146)
3.0.23 (2021-04-30)
- (foxriver76) we now correctly convert the rssi values, workaround for https://github.com/jens-maus/RaspberryMatic/issues/897
- (foxriver76) we made counter states of type "number", was incorrectly "string" (closes #145)
3.0.22 (2021-04-30)
- (foxriver76) parse the dutyCycle state to int (fixes #144)
- (foxriver76) updated dependencies
- (foxriver76) removed unneeded dependency
3.0.21 (2021-04-24)
- (foxriver76) bring back io-package json readme attribute, admin does not fall back to docs as expected (fixes #135)
3.0.20 (2021-04-20)
- (foxriver76) admin/controller has a bug still requiring
common.title
(fixes #133)
3.0.19 (2021-04-16)
- (foxriver76) fixed for custom webinterface port (addresses #117)
3.0.18 (2021-04-05)
- (foxriver76) local link now respects port and protocol
3.0.17 (2021-04-04)
- (foxriver76) correctly identify incomplete requests
3.0.16 (2021-01-31)
- (foxriver76) fixed issue with non-existing objects when using LAN-Gateways
3.0.15 (2021-01-31)
- (foxriver76) Ensures that objects are created if something (devices, variables, programs) created during runtime (fixes #124)
3.0.14 (2021-01-30)
- (foxriver76) fixed pot. crash after reconnecting because of existingStates array
3.0.13 (2021-01-30)
- (foxriver76) ensure to not set states of non-existing RPC objects due to differences in the APIs (fixes #123)
3.0.12 (2021-01-29)
- (foxriver76) we now handle some more edge case errors
3.0.10 (2021-01-27)
- (foxriver76) no build needed
3.0.9 (2021-01-27)
- (foxriver76) fixed gh actions
3.0.8 (2021-01-27)
- (foxriver76) we now wait until objects are created before setting states (fixes #122)
- (foxriver76) added release script
3.0.7 (2021-01-17)
- (foxriver76) we notify the user about aborted connection by CCU during request
3.0.6 (2020-12-25)
- (Hirsch-DE) don't write data points if timestamp is 0"
3.0.5 (2020-12-24)
- (foxriver76) provide possibility to use custom webinterface port, please see FAQ
3.0.4 (2020-12-21)
- (foxriver76) fixed enum translations (changed in API)
- (foxriver76) fixed handling of "favorites" enum
- this can be breaking for some users, please check your enums
2.6.25 (2020-12-16)
- (foxriver76) fixed aliases being removed from enums if they contain
hm-rpc.
2.6.24 (2020-11-03)
- (foxriver76) now states will be accordingly marked to indicate that rega is down when receiving invalid responses
2.6.23 (2020-10-15)
- (foxriver76) fixes for edge case crashes
2.6.22 (2020-09-29)
- (foxriver76) fixed error where alarm states of hm-rpc instances with instance number >= 10 are created for the wrong instance (issue #111)
2.6.20 (2020-09-15)
- (foxriver76) set an explicit object type on extending object (issue #109)
2.6.19 (2020-08-23)
- (foxriver76) fixed issue on syncing service message counter when invisible variables are synchronized
- (foxriver76) fixed issue where value list variables are a string instead of an integer
2.6.17 (2020-08-17)
- (foxriver76) fixed for % scaling of float numbers
2.6.15 (2020-08-08)
- (foxriver76) fixed potential issues with scaling of % values as in https://github.com/ioBroker/ioBroker.hm-rpc/issues/263
2.6.14 (2020-06-11)
- (foxriver76) fixed a potential problem on enum sync, where to many channels could be deleted
2.6.11 (2020-06-11)
- (foxriver76) timeout of requests increased to 90 seconds (its only important to have a timeout to prevent infinite stucking)
2.6.10 (2020-06-10)
- (foxriver76) fixed crash when a user on CCU is an empty string on synchronizing favorites
2.6.9 (2020-05-29)
- (foxriver76) fixed crash when we cannot determine CCU version
2.6.8 (2020-05-26)
- (foxriver76) Script post requests will time out after 15 seconds to prevent stucking in queue if no answer from ccu received
2.6.7 (2020-05-11)
- (foxriver76) fixed some edge cases, reported by Sentry
2.6.6 (2020-05-06)
- (foxriver76) use current time as timestamp if non-existent on initial variables poll
2.6.5 (2020-04-22)
- (foxriver76) improved error handling, no longer use legacy log file
2.6.4 (2020-04-13)
- (foxriver76) now storing scripts in iob file storage
2.6.2 (2020-04-11)
- (foxriver76) minor fixed on a ccu object
2.6.1 (2020-04-04)
- (foxriver76) fixed synchronization
2.6.0 (2020-04-02)
- (foxriver76) sentry plugin support added
2.5.5 (2020-02-17)
- (foxriver76) we are logging the script name in still pending warning from now on
2.5.4 (2020-02-05)
- (foxriver76) made port fully configurable, also with https enabled
2.5.3 (2020-01-15)
- (foxriver76) improved error handling in edge cases and more verbose logging on errors
2.5.2 (2019-12-29)
- (foxriver76) fixed issue which originated by undefined tclsh alias on CCU for
dutycycle.fn
script
2.5.1 (2019-12-14)
- (foxriver76) no longer use
adapter.objects
- (foxriver76) js-controller v > 2 required
2.4.12 (2019-09-26)
- (foxriver76) fixed bug which leads to alarm counter showing the number of service messages
2.4.10 (2019-09-17)
- (foxriver76) we set enum name as a translation object again
2.4.9 (2019-09-04)
- (foxriver76) fixed minor bug which prevented correct room sync
- (foxriver76) in 2.4.6 we implemented the mechanism for hm-rega and rpc, in fact we should only delete hm-rpc devices, because rega will be added on ioB side (can't be done in CCU)
2.4.7 (2019-08-28)
- (foxriver76) fixed another legacy bug, which prevented some enums from getting the correct name
2.4.6 (2019-08-11)
- (foxriver76) only deleting hm adapter objects from enums
2.4.4 (2019-08-02)
- (foxriver76) fixed enum sync and improved logging
2.4.2 (2019-07-23)
- (foxriver76) lc and ts for alarm states are now valid formatted for js-controller
2.4.1 (2019-07-13)
- (foxriver76) also poll invisible vars if configured
2.4.0 (2019-07-03)
- (foxriver76) added possibility to synchronize hidden variables
2.3.3 (2019-04-05)
- (foxriver76) added more system info states when syncing duty cycle
- (foxriver76) when setting ts, do it in ms
2.3.2 (2019-03-10)
- (foxriver76) when ccu sysvar is nan, replace it by null
2.3.1 (2019-03-07)
- (foxriver76) also unescape %0A (\n)
- (foxriver76) remove line break in a firmware version
2.3.0 (2019-02-07)
- (foxriver76) implemented messagebox
2.2.2 (2019-02-04)
- (foxriver76) show the correct number of service messages even if automatic checking is enabled
2.2.1 (2019-01-29)
- (foxriver76) create alarm states with the correct name instead of renaming on restart
- (foxriver76) fixed to enabled acknowledging servicemessages for all instance types
2.2.0 (2019-01-26)
- (foxriver76) reworked alarm states, see FAQ
- (foxriver76) fixed where virtual devices were not named
2.1.8 (2019-01-24)
- (foxriver76) from now on we are displaying the firmware version instead of coprocessor fw version
- (foxriver76) we are making sure to prevent a CCU3 being exposed as a CCU2
- (foxriver76) fixed renaming of alarms on start
2.1.7 (2019-01-21)
- (foxriver76) fixed the bug that all alarms of devices are in hm-rpc rfd instance or non existent if no rpc instance existed
- (foxriver76) fixed bug where datapoints were not named
2.1.6 (2019-01-20)
- (foxriver76) updated state when the same value is set with another timestamp
- (foxriver76) reverted the duty cycle script
- (foxriver76) fixed for parse errors on -inf values
2.1.3 (2019-01-14)
- (foxriver76) also decode string values when setting foreign states
- (foxriver76) added more translations
2.1.2 (2019-01-10)
- (foxriver76) fixed duty cycle script
- (foxriver76) fixed bug where state units were ignored for all except rfd
2.1.0 (2019-01-07)
- (foxriver76) usage of adapter-core
- (bluefox) compact mode compatibility
2.0.1 (2019-01-01)
- (foxriver76) fixed error that prevented setting umlauts to system variables in ioBroker
- (foxriver76) usage and application of eslint
2.0.0 (2018-11-28)
- (foxriver76) Https checkbox added
- (foxriver76) Https can be used instead of http
- (foxriver76) Added possibility to authenticate on API
- (foxriver76) de- and encryption added
1.7.2 (2018-07-29)
- (bluefox) Configuration dialog was corrected
1.7.1 (2018-06-25)
- (bluefox) Forbidden characters were replaced
1.7.0 (2018-01-26)
- (bluefox) Ready for Admin3
1.6.6 (2017-09-23)
- (AlGu1) Fixed error if Lan Interfaces exits
1.6.5 (2017-09-10)
- (AlGu1) Change adapter logging of new values to debug
1.6.4 (2017-09-10)
- (AlGu1) Config Settings changed to set defaults after updated adapter
1.6.3 (2017-09-06)
- (AlGu1) Read values from CCU in raw format and create JSON string and object in adapter
1.6.2 (2017-09-05)
- (AlGu1) dutycycle.fn script changed for better compatibility without ReGaHss Beta version
1.6.1 (2017-09-05)
- (AlGu1) Error in script file fixed
1.6.0 (2017-09-05)
- (AlGu1) Read DutyCycle and other params from
listBidcosInterfaces
1.5.0 (2017-06-29)
- (Apollon77) Also updated names of states when syncing with CCU
1.4.8 (2017-05-24)
- (bluefox) Fixed values conversion for CUxD
1.4.4 (2017-02-28)
- (Apollon77) small fixed (issue #23)
1.4.3 (2017-02-01)
- (Apollon77) respect settings and only sync variables and programs if selected in settings (issue #22)
1.4.2 (2017-01-30)
- (bluefox) remove error log in CCU by start
1.4.1 (2017-01-16)
- (bluefox) merge rooms, functions and favorites with existing one
1.4.0 (2017-01-15)
- (jens-maus) Add HMIP support
1.3.0 (2016-08-23)
- (bluefox) updated states only if changed
1.2.1 (2016-07-15)
- (nobody) fixed initial read of states
1.2.0 (2016-05-27)
- (bluefox) read variables anew if connection of rfd detected
- (bluefox) read alarms
- (bluefox) support for acknowledgment of alarms
1.1.1 (2016-05-27)
- (bluefox) fixed min/max for variables
1.1.0 (2016-04-19)
- (bluefox) change timestamp and last change of states
1.0.0 (2016-04-19)
- (bluefox) detect disconnection and handle it
0.3.7 (2016-04-18)
- (bluefox) fixed error with polling trigger
0.3.6 (2016-03-12)
- (bluefox) fixed read data points
0.3.5 (2016-03-12)
- (bluefox) remove deprecated unescape
0.3.4 (2016-03-09)
- (bluefox) remove deprecated unescape
0.3.3 (2016-03-01)
- (bluefox) remove deprecated unescape
- (bluefox) added connection state
0.3.2 (2016-03-01)
- (bluefox) remove deprecated unescape
0.3.1 (2016-02-29)
- (bluefox) fixed dimmer and blinds values at start
0.3.0 (2016-02-28)
- (bluefox) remove deprecated unescape
0.2.1 (2015-03-25)
- (bluefox) fixed "\n" in values
0.2.0 (2015-03-24)
- (bluefox) implement check init function
0.1.16 (2015-01-04)
- (bluefox) catch errors if states deleted
0.1.15 (2015-01-03)
- (bluefox) added hm-rpc as dependency
0.1.14 (2015-01-03)
- (bluefox) enabled npm install
0.1.13 (2014-12-11)
- (bluefox) processed errors
0.1.12 (2014-12-10)
- (bluefox) updated devices if hm-rpc updates the device list
0.1.11 (2014-12-06)
- (bluefox) updated devices if hm-rpc updates the device list
0.1.10 (2014-11-21)
- (bluefox) support of new naming concept with no parents and children
0.1.9 (2014-11-11)
- (bluefox) fixed error with stopping adapter
0.1.8 (2014-10-22)
- (bluefox) fixed error with scripts
- (bluefox) added gruntfile.js and removed jscs warnings
0.1.7
- (Bluefox, Hobbyquaker) fixed bug if no programs or variables exist
0.1.6
- (hobbyquaker) added common.role for variables
- (hobbyquaker) get state values
- (hobbyquaker) queue device/channel renaming
0.1.5
- (hobbyquaker) enum fixes
0.1.4
- (hobbyquaker) fixes
- (hobbyquaker) added settings ui
0.1.3
- (hobbyquaker) common.children vs children
0.1.2
- (hobbyquaker) Fixed common.children in getPrograms
0.1.1
- (hobbyquaker) Fixed common.name attribute
License
The MIT License (MIT)
Copyright (c) 2014-2024 bluefox [email protected]
Copyright (c) 2014 hobbyquaker
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.