Homebridge MELCloud Control
Homebridge plugin for Air Conditioner, Heat Pump and Energy Recovery Ventilation Lossnay, manufactured by Mistsubishi and connected to MELCloud.
Package Requirements
| Package | Installation | Role | Required | | --- | --- | --- | --- | | Homebridge v2.0 | Homebridge Wiki | HomeKit Bridge | Required ab v3.0.0 | | Config UI X | Config UI X Wiki | Homebridge Web User Interface | Required ab v3.0.0| | MELCloud | Plug-In Wiki | Homebridge Plug-In | Required |
About The Plugin
- All devices are detected automatically.
- Control devices over MELCloud server.
- Support multiple accounts, buildings, floors, areas.
- Support temperature display units
Celsius/Fahrenheit
. - Support assing inividual operating mode for
Heat/Cool/Auto
. - Support direct
Presets
control using extraButtons
, switch it toOFF
restore previous device state. - Support direct
Functions
control using extraButtons
, switch it toOFF
restore previous device state. - Support detect all device states using extra
Sensors
. - Support automations, shortcuts and Siri.
- Support external integrations, RESTFul, MQTT.
- Control devices over local network You need use ESP module and Tasmota Control plugin.
Control Mode
- Air Conditioner:
- Heater Cooler:
- Power
ON/OFF
. - Operating mode
AUTO/HEAT/COOL/POWER OFF
. - Temperature
HEATING/COOLING/AUTO
. - Fan speed
OFF/1/2/3/4/5/AUTO
. - Swing mode
AUTO/SWING
. - Physical lock controls
LOCK/UNLOCK
. - Temperature display unit
°F/°C
.
- Power
- Thermostat:
- Power
ON/OFF
. - Operating mode
POWER OFF/HEAT/COOL/AUTO
. - Temperature
HEATING/COOLING/AUTO
. - Temperature display unit
°F/°C
. - Assign operating mode for
HEAT/AUTO
- Power
- Buttons:
- For direct device control.
- Power
ON/OFF
. - Operating mode
HEAT/DRY/COOL/FAN/AUTO
. - Physical lock controls
LOCK/UNLOCK
. - Vane H mode
AUTO/1/2/3/4/5/SPLIT/SWING
. - Vane V mode
AUTO/1/2/3/4/5/SWING
. - Fan speed mode
AUTO/1/2/3/4/5
. - Presets
SET/UNSET
.
- Power
- For direct device control.
- Sensors:
- For automation and notifications.
- Power
ON/OFF
. - Operating mode
HEAT/DRY/COOL/FAN/AUTO
. - Physical lock controls
LOCK/UNLOCK
. - Vane H mode
AUTO/1/2/3/4/5/SPLIT/SWING
. - Vane V mode
AUTO/1/2/3/4/5/SWING
. - Fan speed mode
AUTO/1/2/3/4/5/
. - Presets
ACTIV/UNACTIV
. - Room temperature.
- Outdoor temperature.
- Power
- For automation and notifications.
- Heater Cooler:
- Heat Pump:
- Heater Cooler:
- Heat Pump:
- Power
ON/OFF
. - Operating mode
HEAT/COOL
. - Outdoor temperature
GET
. - Physical lock controls all Zones and Hot Water Tank
LOCK/UNLOCK
. - Temperature display unit
°F/°C
.
- Power
- Zone 1 and 2:
- Operating mode heat
AUTO/HEAT/COOL
-CURVE/HEAT THERMOSTAT/HEAT FLOW
. - Operating mode cool
HEAT/COOL
-COOL THERMOSTAT/COOL FLOW
. - Temperature
HEATING/COOLING
. - Physical lock controls
LOCK/UNLOCK
.
- Operating mode heat
- Hot Water Tank:
- Operating mode
AUTO/HEAT
-AUTO/HEAT NOW
. - Temperature
SET/GET
. - Physical lock controls
LOCK/UNLOCK
.
- Operating mode
- Heat Pump:
- Thermostat:
- Heat Pump:
- Power
ON/OFF
. - Operating mode
HEAT/COOL
. - Outdoor temperature
GET
. - Temperature display unit
°F/°C
.
- Power
- Zone 1 and 2:
- Operating mode heat
HEAT/COOL/AUTO
-HEAT THERMOSTAT/HEAT FLOW/CURVE
. - Operating mode cool
HEAT/COOL
-COOL THERMOSTAT/COOL FLOW
. - Temperature
HEATING/COOLING
.
- Operating mode heat
- Hot Water Tank:
- Operating mode
HEAT/AUTO
-HEAT NOW, AUTO
. - Temperature
SET/GET
.
- Operating mode
- Heat Pump:
- Buttons:
- For direct device control.
- Power
ON/OFF
. - Operating mode
HEAT/COOL/CURVE/HOLIDAY/AUTO HOT WATER/ECO HOT WATER/FORCE HOT WATER
. - Physical lock controls
LOCK/UNLOCK
. - Presets
SET/UNSET
.
- Power
- For direct device control.
- Sensors:
- For automation and notifications.
- Power
ON/OFF
. - Operating mode
HEAT/COOL/CURVE/HOLIDAY/AUTO HOT WATER/ECO HOT WATER/FORCE HOT WATER
. - Physical lock controls
LOCK/UNLOCK
. - Presets
ACTIV/UNACTIV
. - Outdoor temperature.
- Zone 1 temperature.
- Zone 2 temperature.
- Water tank temperature.
- Flow Temperature Zone 1, 2, Hot Water.
- Return Temperature Zone 1, 2, Hot Water.
- Power
- For automation and notifications.
- Heater Cooler:
- Energy Recovery Ventilation Lossnay:
- Heater Cooler:
- Power
ON/OFF
. - Operating mode
AUTO/HEAT/COOL/POWER OFF
-AUTO, LOSSNAY, BYPASS, POWER OFF
. - Fan speed
OFF/1/2/3/4/AUTO
. - Temperature display unit
°F/°C
.
- Power
- Thermostat:
- Power
ON/OFF
. - Operating mode
POWER OFF/HEAT/COOL/AUTO
-POWER OFF, LOSSNAY, BYPASS, AUTO
. - Temperature display unit
°F/°C
.
- Power
- Buttons:
- For direct device control.
- Power
ON/OFF
. - Operating mode
LOSSNAY/BYPASS/AUTO/NIGHT PURGE
. - Fan speed mode
AUTO/1/2/3/4
. - Presets
SET/UNSET
.
- Power
- For direct device control.
- Sensors:
- For automation and notifications.
- Power
ON/OFF
. - Operating mode
LOSSNAY/BYPASS/AUTO/NIGHT PURGE
. - Fan speed mode
AUTO/1/2/3/4
. - Presets
ACTIV/UNACTIV
. - Room temperature.
- Outdoor temperature.
- Supply temperature.
- Core maintenance.
- Filter maintenance.
- CO2 detected and level.
- PM2.5 air quality and level.
- Power
- For automation and notifications.
- Heater Cooler:
HOME app current device mode display
- In AUTO mode, the tile display current state based on current mode:
- In HEATING mode, th tile display current state as HEATING - orange
- In COOLING mode, the tile display current state as COOLING - blue
- In DRY mode, the tile display current state as IDLE - black
- In FAN mode, the tile display current state as IDLE - black
- In IDLE mode, the tile display current state as IDLE - black
- In INACTIVE mode, the tile display current state as INACTIVE - transparent
AUTO Mode
- Heather/Cooler
- In this mode we can set heathing threshold and cooling threshold temperature:
- Target temperature is calculated as a middle value between
LO
andHI
and the rest is calculated internally.
- Thermostat
- In this mode we can set only target temperature:
- Target temperature issend to device and calculated internally:
- Calculation method in device internally:
- If the room temperature
<
Heating Setpoint, the unit will be set to HEAT with a setpoint of 23°C. - In HEAT, if the room temperature
>
Heating Setpoint+
1°C, the unit will be set to FAN. - In FAN, if the room temperature
>
Cooling Setpoint, the unit will be set to COOL with a setpoint of 19°C. - In COOL, if the room temperature
<
Cooling Setpoint-
1°C, the unit will be set to FAN. - In FAN, if the room temperature
<
Heating Setpoint, the unit will be set to HEAT with a setpoint of 23°C.
- If the room temperature
- The image shows Heating Setpoint of 19°C and a Cooling Setpoint of 23°C.
Configuration
- Run this plugin as a Child Bridge (Highly Recommended), this prevent crash Homebridge if plugin crashes.
- Install and use Homebridge Config UI X to configure this plugin, required for version v3 and above.
- The
sample-config.json
can be edited and used as an alternative.
| Key | Description |
| --- | --- |
| name
| Here set the own account name. |
| user
| Here set the MELCloud username. |
| passwd
| Here set the MELCloud password. |
| language
| Here select the MELCloud language. |
| ataDevices
| Array of ATA devices created automatically after login to MELCloud from plugin config UI. |
| ataDevices.id
| Read only data, do not change it. |
| ataDevices.type
| Read only data, do not change it. |
| ataDevices.typeString
| Read only data, do not change it. |
| ataDevices.name
| Here You can schange the Accessory Name
which is exposed to the Homebridge/HomeKit
. |
| ataDevices.displayMode
| Here select device control mode None/Disabled
, Heater/Cooler
, Thermostat
. |
| ataDevices.heatDryFanMode
| Here select the operatiing mode for Heat
, if this mode is not supported, it will be disabled. |
| ataDevices.coolDryFanMode
| Here select the operatiing mode for Cool
, if this mode is not supported, it will be disabled. |
| ataDevices.autoDryFanMode
| Here select the operatiing mode for Auto
, if this mode is not supported, it will be disabled.. |
| ataDevices.temperatureSensor
| This enable extra Room
temperature sensors to use with automations in HomeKit app. |
| ataDevices.temperatureSensorOutdoor
| This enable extra Outdoor
temperature sensors to use with automations in HomeKit app. |
| ataDevices.refreshInterval
| Here set the background devices state refresh time in (sec), default 5s
. |
| ataDevices.presets
| Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. |
| ataDevices.presets.id
| Read only data, do not change it. |
| ataDevices.presets.name
| Here You can schange the Preset Name
which is exposed to the Homebridge/HomeKit
. |
| ataDevices.presets.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors
| Array of buttons sensors. |
| buttonsSensors.name
| Here set Button Name
which You want expose to the Homebridge/HomeKit
. |
| buttonsSensors.mode
| Here select button mode, VH - Vane Horizontal, VV - Vane Horizontal. |
| buttonsSensors.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors.namePrefix
| Here enable/disable the accessory name as a prefix for button/sensor name. |
| atwDevices
| Array of ATA devices created automatically after login to MELCloud from plugin config UI. |
| atwDevices.id
| Read only data, do not change it. |
| atwDevices.type
| Read only data, do not change it. |
| atwDevices.typeString
| Read only data, do not change it. |
| atwDevices.name
| Here You can schange the Accessory Name
which is exposed to the Homebridge/HomeKit
. |
| atwDevices.displayMode
| Here select main control mode None/Disabled
, Heater/Cooler
, Thermostat
. |
| atwDevices.temperatureSensor
| This enable extra Room
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlow
| This enable extra Flow
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturn
| This enable extra Return
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlowZone1
| This enable extra Flow Zone 1
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturnZone1
| This enable extra Return Zone 1
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlowWaterTank
| This enable extra Flow Water Tank
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturnWaterTank
| This enable extra Return Water Tank
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlowZone2
| This enable extra Flow Zone 2
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturnZone2
| This enable extra Return Zone 2
temperature sensors to use with automations in HomeKit app. |
| atwDevices.refreshInterval
| Here set the background devices state refresh time in (sec), default 5s
. |
| atwDevices.presets
| Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. |
| atwDevices.presets.id
| Read only data, do not change it. |
| atwDevices.presets.name
| Here You can schange the Preset Name
which is exposed to the Homebridge/HomeKit
. |
| atwDevices.presets.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors
| Array of buttons sensors. |
| buttonsSensors.name
| Here set Button Name
which You want expose to the Homebridge/HomeKit
. |
| buttonsSensors.mode
| Here select button mode. |
| buttonsSensors.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors.namePrefix
| Here enable/disable the accessory name as a prefix for button/sensor name. |
| ervDevices
| Array of ATA devices created automatically after login to MELCloud from plugin config UI. |
| ervDevices.id
| Read only data, do not change it. |
| ervDevices.type
| Read only data, do not change it. |
| ervDevices.typeString
| Read only data, do not change it. |
| ervDevices.name
| Here You can schange the Accessory Name
which is exposed to the Homebridge/HomeKit
. |
| ervDevices.displayMode
| Here select main control mode None/Disabled
, Heater/Cooler
, Thermostat
. |
| ervDevices.temperatureSensor
| This enable extra Room
temperature sensors to use with automations in HomeKit app. |
| ervDevices.temperatureSensorOutdoor
| This enable extra Outdoor
temperature sensors to use with automations in HomeKit app. |
| ervDevices.temperatureSensorSupply
| This enable extra Supply
temperature sensors to use with automations in HomeKit app. |
| ervDevices.refreshInterval
| Here set the background devices state refresh time in (sec), default 5s
. |
| ervDevices.presets
| Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. |
| ervDevices.presets.id
| Read only data, do not change it. |
| ervDevices.presets.name
| Here You can schange the Preset Name
which is exposed to the Homebridge/HomeKit
. |
| ervDevices.presets.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors
| Array of buttons sensors. |
| buttonsSensors.name
| Here set Button Name
which You want expose to the Homebridge/HomeKit
. |
| buttonsSensors.mode
| Here select button mode. |
| buttonsSensors.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors.namePrefix
| Here enable/disable the accessory name as a prefix for button/sensor name. |
| refreshInterval
| Here set the background account data refresh time in (sec), default 120s
. |
| enableDebugMode
| This enable deep log in homebridge console. |
| disableLogInfo
| This disable display log values and states on every it change. |
| disableLogDeviceInfo
| This disable display log device info on plugin start. |
| restFul
| This is RSTful server. |
| restFul.enable
| If enabled, RESTful server will start automatically and respond to any path request. |
| restFul.port
| Here set the listening Port
for RESTful server. |
| restFul.debug
| If enabled, deep log will be present in homebridge console for RESTFul server. |
| mqtt
| This is MQTT Broker. |
| mqtt.enable
| If enabled, MQTT Broker will start automatically and publish all awailable PV data. |
| mqtt.host
| Here set the IP Address
or Hostname
for MQTT Broker. |
| mqtt.port
| Here set the Port
for MQTT Broker, default 1883. |
| mqtt.clientId
| Here optional set the Client Id
of MQTT Broker. |
| mqtt.prefix
| Here set the Prefix
for Topic
or leave empty. |
| mqtt.auth
| If enabled, MQTT Broker will use authorization credentials. |
| mqtt.user
| Here set the MQTT Broker user. |
| mqtt.passwd
| Here set the MQTT Broker password. |
| mqtt.debug
| If enabled, deep log will be present in homebridge console for MQTT. |
RESTful Integration
- Port: last 4 numbers of
device Id
, displayed in HB log during start. - POST data as a JSON Object
{OperationMode: 8}
| Method | URL | Path | Response | Type |
| --- | --- | --- | --- | --- |
| GET | http//ip:port
| Info
, State
| {"Power": true, "SetTemperature": 21.5}
| JSON object. |
| Method | URL | Key | Value | Type | Description |
| --- | --- | --- | --- | --- | --- |
| Air Conditioner | | | | | |
| POST | http//ip:port
| Power
| true
, false
| boolean | Power state. |
| | http//ip:port
| HideVaneControls
| true
, false
| boolean | Hide vane controls. |
| | http//ip:port
| HideDryModeControl
| true
, false
| boolean | Hide dry mode control. |
| | http//ip:port
| ProhibitSetTemperature
| true
, false
| boolean | Lock set temperature. |
| | http//ip:port
| ProhibitOperationMode
| true
, false
| boolean | Lock set operating mode. |
| | http//ip:port
| ProhibitPower
| true
, false
| boolean | Lock set power. |
| | http//ip:port
| OperationMode
| 1 - Heat
, 2 - Dry
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | http//ip:port
| FanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
, 5
, 6
| integer | Fan speed. |
| | http//ip:port
| VaneHorizontalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 8 - Split
, 12 - Swing
| integer | Vane H mode. |
| | http//ip:port
| VaneVerticalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 7 - Swing
| integer | Vane V mode. |
| | http//ip:port
| SetTemperature
| 0.0
| float | Room temperature. |
| | http//ip:port
| DefaultCoolingSetTemperature
| 0.0
| float | Default cooling temperature. |
| | http//ip:port
| DefaultHeatingSetTemperature
| 0.0
| float | Default heating temperature. |
| Heat Pump | | | | | |
| POST | http//ip:port
| Power
| true
, false
| boolean | Power state. |
| | http//ip:port
| ForcedHotWaterMode
| true
, false
| boolean | Force hot water. |
| | http//ip:port
| EcoHotWater
| true
, false
| boolean | Eco hot water. |
| | http//ip:port
| HolidayMode
| true
, false
| boolean | Holiday mode. |
| | http//ip:port
| ProhibitZone1
| true
, false
| boolean | Lock control zone 1. |
| | http//ip:port
| ProhibitZone2
| true
, false
| boolean | Lock control zone 2. |
| | http//ip:port
| ProhibitHotWater
| true
, false
| boolean | Lock control hot water. |
| | http//ip:port
| OperationMode
| 0 - Auto
, 1 - Heat
, 2 - Cool
| integer | Operating mode heat pump. |
| | http//ip:port
| OperationModeZone1
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 1. |
| | http//ip:port
| OperationModeZone2
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 2. |
| | http//ip:port
| SetTemperatureZone1
| 0.0
| float | Temperature zone 1. |
| | http//ip:port
| SetTemperatureZone2
| 0.0
| float | Temperature zone 2. |
| | http//ip:port
| SetHeatFlowTemperatureZone1
| 0.0
| float | Heat flow temperature zone 1. |
| | http//ip:port
| SetHeatFlowTemperatureZone2
| 0.0
| float | Heat flow temperature zone 2. |
| | http//ip:port
| SetCoolFlowTemperatureZone1
| 0.0
| float | Cool flow temperature zone 1. |
| | http//ip:port
| SetCoolFlowTemperatureZone2
| 0.0
| float | Cool flow temperature zone 2. |
| | http//ip:port
| SetTankWaterTemperature
| 0.0
| float | Hot water temperature. |
| Energy Recovery Ventilation | | | | | |
| POST | http//ip:port
| Power
| true
, false
| boolean | Power state. |
| | http//ip:port
| NightPurgeMode
| true
, false
| boolean | Night purge mode. |
| | http//ip:port
| HideRoomTemperature
| true
, false
| boolean | Hide room temperature. |
| | http//ip:port
| HideSupplyTemperature
| true
, false
| boolean | Hide supply temperature. |
| | http//ip:port
| HideOutdoorTemperature
| true
, false
| boolean | Hide outdoor temperature. |
| | http//ip:port
| OperationMode
| 1 - Heat
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | http//ip:port
| VentilationMode
| 0 - Lossnay
, 1 - Bypass
, 2 - Auto
| integer | Ventilation mode. |
| | http//ip:port
| SetFanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
| integer | Fan speed. |
| | http//ip:port
| SetTemperature
| 0.0
| float | Room temperature. |
| | http//ip:port
| DefaultCoolingSetTemperature
| 0.0
| float | Default cooling temperature. |
| | http//ip:port
| DefaultHeatingSetTemperature
| 0.0
| float | Default heating temperature. |
MQTT Integration
- Subscribe data as a JSON Object
{"Power": true}
| Direction | Topic | Message | Type |
| --- | --- | --- | --- |
| Publish | Info
, State
| {"Power": true, "SetTemperature": 21.5}
| JSON object. |
| Method | Topic | Key | Value | Type | Description |
| --- | --- | --- | --- | --- | --- |
| Air Conditioner | | | | | |
| Subscribe | Set
| Power
| true
, false
| boolean | Power state. |
| | Set
| HideVaneControls
| true
, false
| boolean | Hide vane controls. |
| | Set
| HideDryModeControl
| true
, false
| boolean | Hide dry mode control. |
| | Set
| ProhibitSetTemperature
| true
, false
| boolean | Lock set temperature. |
| | Set
| ProhibitOperationMode
| true
, false
| boolean | Lock set operating mode. |
| | Set
| ProhibitPower
| true
, false
| boolean | Lock set power. |
| | Set
| OperationMode
| 1 - Heat
, 2 - Dry
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | Set
| FanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
, 5
, 6
| integer | Fan speed. |
| | Set
| VaneHorizontalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 8 - Split
, 12 - Swing
| integer | Vane H mode. |
| | Set
| VaneVerticalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 7 - Swing
| integer | Vane V mode. |
| | Set
| SetTemperature
| 0.0
| float | Room temperature. |
| | Set
| DefaultCoolingSetTemperature
| 23.0
| float | Default cooling temperature. |
| | Set
| DefaultHeatingSetTemperature
| 21.0
| float | Default heating temperature. |
| Heat Pump | | | | | |
| Subscribe | Set
| Power
| true
, false
| boolean | Power state. |
| | Set
| ForcedHotWaterMode
| true
, false
| boolean | Force hot water. |
| | Set
| EcoHotWater
| true
, false
| boolean | Eco hot water. |
| | Set
| HolidayMode
| true
, false
| boolean | Holiday mode. |
| | Set
| ProhibitZone1
| true
, false
| boolean | Lock control zone 1. |
| | Set
| ProhibitZone2
| true
, false
| boolean | Lock control zone 2. |
| | Set
| ProhibitHotWater
| true
, false
| boolean | Lock control hot water. |
| | Set
| OperationMode
| 0 - Auto
, 1 - Heat
, 2 - Cool
| integer | Operating mode heat pump. |
| | Set
| OperationModeZone1
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 1. |
| | Set
| OperationModeZone2
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 2. |
| | Set
| SetTemperatureZone1
| 0.0
| float | Temperature zone 1. |
| | Set
| SetTemperatureZone2
| 0.0
| float | Temperature zone 2. |
| | Set
| SetHeatFlowTemperatureZone1
| 0.0
| float | Heat flow temperature zone 1. |
| | Set
| SetHeatFlowTemperatureZone2
| 0.0
| float | Heat flow temperature zone 2. |
| | Set
| SetCoolFlowTemperatureZone1
| 0.0
| float | Cool flow temperature zone 1. |
| | Set
| SetCoolFlowTemperatureZone2
| 0.0
| float | Cool flow temperature zone 2. |
| | Set
| SetTankWaterTemperature
| 0.0
| float | Hot water temperature. |
| Energy Recovery Ventilation | | | | | |
| Subscribe | Set
| Power
| true
, false
| boolean | Power state. |
| | Set
| NightPurgeMode
| true
, false
| boolean | Night purge mode. |
| | Set
| HideRoomTemperature
| true
, false
| boolean | Hide room temperature. |
| | Set
| HideSupplyTemperature
| true
, false
| boolean | Hide supply temperature. |
| | Set
| HideOutdoorTemperature
| true
, false
| boolean | Hide outdoor temperature. |
| | Set
| OperationMode
| 1 - Heat
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | Set
| VentilationMode
| 0 - Lossnay
, 1 - Bypass
, 2 - Auto
| integer | Ventilation mode. |
| | Set
| SetFanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
| integer | Fan speed. |
| | Set
| SetTemperature
| 0.0
| float | Room temperature. |
| | Set
| DefaultCoolingSetTemperature
| 23.0
| float | Default cooling temperature. |
| | Set
| DefaultHeatingSetTemperature
| 21.0
| float | Default heating temperature. |