homebridge-melcloud-control
v3.3.30
Published
Homebridge plugin to control Mitsubishi Air Conditioner, Heat Pump and Energy Recovery Ventilation.
Downloads
3,603
Maintainers
Readme
Homebridge MELCloud Control
Homebridge plugin for Air Conditioner, Heat Pump and Energy Recovery Ventilation Lossnay, manufactured by Mistsubishi and connected to MELCloud.
Package Requirements
| Package | Installation | Role | Required | | --- | --- | --- | --- | | Homebridge v2.0 | Homebridge Wiki | HomeKit Bridge | Required ab v3.0.0 | | Config UI X | Config UI X Wiki | Homebridge Web User Interface | Required ab v3.0.0| | MELCloud | Plug-In Wiki | Homebridge Plug-In | Required |
About The Plugin
- All devices are detected automatically.
- Control devices over MELCloud server.
- Support multiple accounts, buildings, floors, areas.
- Support temperature display units
Celsius/Fahrenheit
. - Support assing inividual operating mode for
Heat/Cool/Auto
. - Support direct
Presets
control using extraButtons
, switch it toOFF
restore previous device state. - Support direct
Functions
control using extraButtons
, switch it toOFF
restore previous device state. - Support detect all device states using extra
Sensors
. - Support automations, shortcuts and Siri.
- Support external integrations, RESTFul, MQTT.
- Control devices over local network You need use ESP module and Tasmota Control plugin.
Control Mode
- Air Conditioner:
- Heater Cooler:
- Power
ON/OFF
. - Operating mode
AUTO/HEAT/COOL/POWER OFF
. - Temperature
HEATING/COOLING/AUTO
. - Fan speed
OFF/1/2/3/4/5/AUTO
. - Swing mode
AUTO/SWING
. - Physical lock controls
LOCK/UNLOCK
. - Temperature display unit
°F/°C
.
- Power
- Thermostat:
- Power
ON/OFF
. - Operating mode
POWER OFF/HEAT/COOL/AUTO
. - Temperature
HEATING/COOLING/AUTO
. - Temperature display unit
°F/°C
. - Assign operating mode for
HEAT/AUTO
- Power
- Buttons:
- For direct device control.
- Power
ON/OFF
. - Operating mode
HEAT/DRY/COOL/FAN/AUTO
. - Physical lock controls
LOCK/UNLOCK
. - Vane H mode
AUTO/1/2/3/4/5/SPLIT/SWING
. - Vane V mode
AUTO/1/2/3/4/5/SWING
. - Fan speed mode
AUTO/1/2/3/4/5
. - Presets
SET/UNSET
.
- Power
- For direct device control.
- Sensors:
- For automation and notifications.
- Power
ON/OFF
. - Operating mode
HEAT/DRY/COOL/FAN/AUTO
. - Physical lock controls
LOCK/UNLOCK
. - Vane H mode
AUTO/1/2/3/4/5/SPLIT/SWING
. - Vane V mode
AUTO/1/2/3/4/5/SWING
. - Fan speed mode
AUTO/1/2/3/4/5/
. - Presets
ACTIV/UNACTIV
. - Room temperature.
- Outdoor temperature.
- Power
- For automation and notifications.
- Heater Cooler:
- Heat Pump:
- Heater Cooler:
- Heat Pump:
- Power
ON/OFF
. - Operating mode
HEAT/COOL
. - Outdoor temperature
GET
. - Physical lock controls all Zones and Hot Water Tank
LOCK/UNLOCK
. - Temperature display unit
°F/°C
.
- Power
- Zone 1 and 2:
- Operating mode heat
AUTO/HEAT/COOL
-CURVE/HEAT THERMOSTAT/HEAT FLOW
. - Operating mode cool
HEAT/COOL
-COOL THERMOSTAT/COOL FLOW
. - Temperature
HEATING/COOLING
. - Physical lock controls
LOCK/UNLOCK
.
- Operating mode heat
- Hot Water Tank:
- Operating mode
AUTO/HEAT
-AUTO/HEAT NOW
. - Temperature
SET/GET
. - Physical lock controls
LOCK/UNLOCK
.
- Operating mode
- Heat Pump:
- Thermostat:
- Heat Pump:
- Power
ON/OFF
. - Operating mode
HEAT/COOL
. - Outdoor temperature
GET
. - Temperature display unit
°F/°C
.
- Power
- Zone 1 and 2:
- Operating mode heat
HEAT/COOL/AUTO
-HEAT THERMOSTAT/HEAT FLOW/CURVE
. - Operating mode cool
HEAT/COOL
-COOL THERMOSTAT/COOL FLOW
. - Temperature
HEATING/COOLING
.
- Operating mode heat
- Hot Water Tank:
- Operating mode
HEAT/AUTO
-HEAT NOW, AUTO
. - Temperature
SET/GET
.
- Operating mode
- Heat Pump:
- Buttons:
- For direct device control.
- Power
ON/OFF
. - Operating mode
HEAT/COOL/CURVE/HOLIDAY/AUTO HOT WATER/ECO HOT WATER/FORCE HOT WATER
. - Physical lock controls
LOCK/UNLOCK
. - Presets
SET/UNSET
.
- Power
- For direct device control.
- Sensors:
- For automation and notifications.
- Power
ON/OFF
. - Operating mode
HEAT/COOL/CURVE/HOLIDAY/AUTO HOT WATER/ECO HOT WATER/FORCE HOT WATER
. - Physical lock controls
LOCK/UNLOCK
. - Presets
ACTIV/UNACTIV
. - Outdoor temperature.
- Zone 1 temperature.
- Zone 2 temperature.
- Water tank temperature.
- Flow Temperature Zone 1, 2, Hot Water.
- Return Temperature Zone 1, 2, Hot Water.
- Power
- For automation and notifications.
- Heater Cooler:
- Energy Recovery Ventilation Lossnay:
- Heater Cooler:
- Power
ON/OFF
. - Operating mode
AUTO/HEAT/COOL/POWER OFF
-AUTO, LOSSNAY, BYPASS, POWER OFF
. - Fan speed
OFF/1/2/3/4/AUTO
. - Temperature display unit
°F/°C
.
- Power
- Thermostat:
- Power
ON/OFF
. - Operating mode
POWER OFF/HEAT/COOL/AUTO
-POWER OFF, LOSSNAY, BYPASS, AUTO
. - Temperature display unit
°F/°C
.
- Power
- Buttons:
- For direct device control.
- Power
ON/OFF
. - Operating mode
LOSSNAY/BYPASS/AUTO/NIGHT PURGE
. - Fan speed mode
AUTO/1/2/3/4
. - Presets
SET/UNSET
.
- Power
- For direct device control.
- Sensors:
- For automation and notifications.
- Power
ON/OFF
. - Operating mode
LOSSNAY/BYPASS/AUTO/NIGHT PURGE
. - Fan speed mode
AUTO/1/2/3/4
. - Presets
ACTIV/UNACTIV
. - Room temperature.
- Outdoor temperature.
- Supply temperature.
- Core maintenance.
- Filter maintenance.
- CO2 detected and level.
- PM2.5 air quality and level.
- Power
- For automation and notifications.
- Heater Cooler:
HOME app current device mode display
- In AUTO mode, the tile display current state based on current mode:
- In HEATING mode, th tile display current state as HEATING - orange
- In COOLING mode, the tile display current state as COOLING - blue
- In DRY mode, the tile display current state as IDLE - black
- In FAN mode, the tile display current state as IDLE - black
- In IDLE mode, the tile display current state as IDLE - black
- In INACTIVE mode, the tile display current state as INACTIVE - transparent
AUTO Mode
- Heather/Cooler
- In this mode we can set heathing threshold and cooling threshold temperature:
- Target temperature is calculated as a middle value between
LO
andHI
and the rest is calculated internally.
- Thermostat
- In this mode we can set only target temperature:
- Target temperature issend to device and calculated internally:
- Calculation method in device internally:
- If the room temperature
<
Heating Setpoint, the unit will be set to HEAT with a setpoint of 23°C. - In HEAT, if the room temperature
>
Heating Setpoint+
1°C, the unit will be set to FAN. - In FAN, if the room temperature
>
Cooling Setpoint, the unit will be set to COOL with a setpoint of 19°C. - In COOL, if the room temperature
<
Cooling Setpoint-
1°C, the unit will be set to FAN. - In FAN, if the room temperature
<
Heating Setpoint, the unit will be set to HEAT with a setpoint of 23°C.
- If the room temperature
- The image shows Heating Setpoint of 19°C and a Cooling Setpoint of 23°C.
Configuration
- Run this plugin as a Child Bridge (Highly Recommended), this prevent crash Homebridge if plugin crashes.
- Install and use Homebridge Config UI X to configure this plugin, required for version v3 and above.
- The
sample-config.json
can be edited and used as an alternative.
| Key | Description |
| --- | --- |
| name
| Here set the own account name. |
| user
| Here set the MELCloud username. |
| passwd
| Here set the MELCloud password. |
| language
| Here select the MELCloud language. |
| ataDevices
| Array of ATA devices created automatically after login to MELCloud from plugin config UI. |
| ataDevices.id
| Read only data, do not change it. |
| ataDevices.type
| Read only data, do not change it. |
| ataDevices.typeString
| Read only data, do not change it. |
| ataDevices.name
| Here You can schange the Accessory Name
which is exposed to the Homebridge/HomeKit
. |
| ataDevices.displayMode
| Here select device control mode None/Disabled
, Heater/Cooler
, Thermostat
. |
| ataDevices.heatDryFanMode
| Here select the operatiing mode for Heat
, if this mode is not supported, it will be disabled. |
| ataDevices.coolDryFanMode
| Here select the operatiing mode for Cool
, if this mode is not supported, it will be disabled. |
| ataDevices.autoDryFanMode
| Here select the operatiing mode for Auto
, if this mode is not supported, it will be disabled.. |
| ataDevices.temperatureSensor
| This enable extra Room
temperature sensors to use with automations in HomeKit app. |
| ataDevices.temperatureSensorOutdoor
| This enable extra Outdoor
temperature sensors to use with automations in HomeKit app. |
| ataDevices.presets
| Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. |
| ataDevices.presets.id
| Read only data, do not change it. |
| ataDevices.presets.name
| Here You can schange the Preset Name
which is exposed to the Homebridge/HomeKit
. |
| ataDevices.presets.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors
| Array of buttons sensors. |
| buttonsSensors.name
| Here set Button Name
which You want expose to the Homebridge/HomeKit
. |
| buttonsSensors.mode
| Here select button mode, VH - Vane Horizontal, VV - Vane Horizontal. |
| buttonsSensors.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors.namePrefix
| Here enable/disable the accessory name as a prefix for button/sensor name. |
| atwDevices
| Array of ATA devices created automatically after login to MELCloud from plugin config UI. |
| atwDevices.id
| Read only data, do not change it. |
| atwDevices.type
| Read only data, do not change it. |
| atwDevices.typeString
| Read only data, do not change it. |
| atwDevices.name
| Here You can schange the Accessory Name
which is exposed to the Homebridge/HomeKit
. |
| atwDevices.displayMode
| Here select main control mode None/Disabled
, Heater/Cooler
, Thermostat
. |
| atwDevices.temperatureSensor
| This enable extra Room
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlow
| This enable extra Flow
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturn
| This enable extra Return
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlowZone1
| This enable extra Flow Zone 1
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturnZone1
| This enable extra Return Zone 1
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlowWaterTank
| This enable extra Flow Water Tank
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturnWaterTank
| This enable extra Return Water Tank
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorFlowZone2
| This enable extra Flow Zone 2
temperature sensors to use with automations in HomeKit app. |
| atwDevices.temperatureSensorReturnZone2
| This enable extra Return Zone 2
temperature sensors to use with automations in HomeKit app. |
| atwDevices.presets
| Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. |
| atwDevices.presets.id
| Read only data, do not change it. |
| atwDevices.presets.name
| Here You can schange the Preset Name
which is exposed to the Homebridge/HomeKit
. |
| atwDevices.presets.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors
| Array of buttons sensors. |
| buttonsSensors.name
| Here set Button Name
which You want expose to the Homebridge/HomeKit
. |
| buttonsSensors.mode
| Here select button mode. |
| buttonsSensors.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors.namePrefix
| Here enable/disable the accessory name as a prefix for button/sensor name. |
| ervDevices
| Array of ATA devices created automatically after login to MELCloud from plugin config UI. |
| ervDevices.id
| Read only data, do not change it. |
| ervDevices.type
| Read only data, do not change it. |
| ervDevices.typeString
| Read only data, do not change it. |
| ervDevices.name
| Here You can schange the Accessory Name
which is exposed to the Homebridge/HomeKit
. |
| ervDevices.displayMode
| Here select main control mode None/Disabled
, Heater/Cooler
, Thermostat
. |
| ervDevices.temperatureSensor
| This enable extra Room
temperature sensors to use with automations in HomeKit app. |
| ervDevices.temperatureSensorOutdoor
| This enable extra Outdoor
temperature sensors to use with automations in HomeKit app. |
| ervDevices.temperatureSensorSupply
| This enable extra Supply
temperature sensors to use with automations in HomeKit app. |
| ervDevices.presets
| Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. |
| ervDevices.presets.id
| Read only data, do not change it. |
| ervDevices.presets.name
| Here You can schange the Preset Name
which is exposed to the Homebridge/HomeKit
. |
| ervDevices.presets.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors
| Array of buttons sensors. |
| buttonsSensors.name
| Here set Button Name
which You want expose to the Homebridge/HomeKit
. |
| buttonsSensors.mode
| Here select button mode. |
| buttonsSensors.displayType
| Here select display type in HomeKit, 0 - None/Disabled
, 1 - Outlet
, 2 - Switch
, 3 - Motion Sensor
, 4 - Occupancy Sensor
, 5 - Contact Sensor
. |
| buttonsSensors.namePrefix
| Here enable/disable the accessory name as a prefix for button/sensor name. |
| refreshInterval
| Here set the background account data refresh time in (sec), default 120s
. |
| deviceRefreshInterval
| Here set the background devices state refresh time in (sec), default 5s
. |
| enableDebugMode
| This enable deep log in homebridge console. |
| disableLogInfo
| This disable display log values and states on every it change. |
| disableLogDeviceInfo
| This disable display log device info on plugin start. |
| restFul
| This is RSTful server. |
| restFul.enable
| If enabled, RESTful server will start automatically and respond to any path request. |
| restFul.port
| Here set the listening Port
for RESTful server. |
| restFul.debug
| If enabled, deep log will be present in homebridge console for RESTFul server. |
| mqtt
| This is MQTT Broker. |
| mqtt.enable
| If enabled, MQTT Broker will start automatically and publish all awailable PV data. |
| mqtt.host
| Here set the IP Address
or Hostname
for MQTT Broker. |
| mqtt.port
| Here set the Port
for MQTT Broker, default 1883. |
| mqtt.clientId
| Here optional set the Client Id
of MQTT Broker. |
| mqtt.prefix
| Here set the Prefix
for Topic
or leave empty. |
| mqtt.auth
| If enabled, MQTT Broker will use authorization credentials. |
| mqtt.user
| Here set the MQTT Broker user. |
| mqtt.passwd
| Here set the MQTT Broker password. |
| mqtt.debug
| If enabled, deep log will be present in homebridge console for MQTT. |
RESTful Integration
- Port: last 4 numbers of
device Id
, displayed in HB log during start. - POST data as a JSON Object
{OperationMode: 8}
| Method | URL | Path | Response | Type |
| --- | --- | --- | --- | --- |
| GET | http//ip:port
| Info
, State
| {"Power": true, "SetTemperature": 21.5}
| JSON object. |
| Method | URL | Key | Value | Type | Description |
| --- | --- | --- | --- | --- | --- |
| Air Conditioner | | | | | |
| POST | http//ip:port
| Power
| true
, false
| boolean | Power state. |
| | http//ip:port
| HideVaneControls
| true
, false
| boolean | Hide vane controls. |
| | http//ip:port
| HideDryModeControl
| true
, false
| boolean | Hide dry mode control. |
| | http//ip:port
| ProhibitSetTemperature
| true
, false
| boolean | Lock set temperature. |
| | http//ip:port
| ProhibitOperationMode
| true
, false
| boolean | Lock set operating mode. |
| | http//ip:port
| ProhibitPower
| true
, false
| boolean | Lock set power. |
| | http//ip:port
| OperationMode
| 1 - Heat
, 2 - Dry
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | http//ip:port
| FanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
, 5
, 6
| integer | Fan speed. |
| | http//ip:port
| VaneHorizontalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 8 - Split
, 12 - Swing
| integer | Vane H mode. |
| | http//ip:port
| VaneVerticalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 7 - Swing
| integer | Vane V mode. |
| | http//ip:port
| SetTemperature
| 0.0
| float | Room temperature. |
| | http//ip:port
| DefaultCoolingSetTemperature
| 0.0
| float | Default cooling temperature. |
| | http//ip:port
| DefaultHeatingSetTemperature
| 0.0
| float | Default heating temperature. |
| Heat Pump | | | | | |
| POST | http//ip:port
| Power
| true
, false
| boolean | Power state. |
| | http//ip:port
| ForcedHotWaterMode
| true
, false
| boolean | Force hot water. |
| | http//ip:port
| EcoHotWater
| true
, false
| boolean | Eco hot water. |
| | http//ip:port
| HolidayMode
| true
, false
| boolean | Holiday mode. |
| | http//ip:port
| ProhibitZone1
| true
, false
| boolean | Lock control zone 1. |
| | http//ip:port
| ProhibitZone2
| true
, false
| boolean | Lock control zone 2. |
| | http//ip:port
| ProhibitHotWater
| true
, false
| boolean | Lock control hot water. |
| | http//ip:port
| OperationMode
| 0 - Auto
, 1 - Heat
, 2 - Cool
| integer | Operating mode heat pump. |
| | http//ip:port
| OperationModeZone1
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 1. |
| | http//ip:port
| OperationModeZone2
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 2. |
| | http//ip:port
| SetTemperatureZone1
| 0.0
| float | Temperature zone 1. |
| | http//ip:port
| SetTemperatureZone2
| 0.0
| float | Temperature zone 2. |
| | http//ip:port
| SetHeatFlowTemperatureZone1
| 0.0
| float | Heat flow temperature zone 1. |
| | http//ip:port
| SetHeatFlowTemperatureZone2
| 0.0
| float | Heat flow temperature zone 2. |
| | http//ip:port
| SetCoolFlowTemperatureZone1
| 0.0
| float | Cool flow temperature zone 1. |
| | http//ip:port
| SetCoolFlowTemperatureZone2
| 0.0
| float | Cool flow temperature zone 2. |
| | http//ip:port
| SetTankWaterTemperature
| 0.0
| float | Hot water temperature. |
| Energy Recovery Ventilation | | | | | |
| POST | http//ip:port
| Power
| true
, false
| boolean | Power state. |
| | http//ip:port
| NightPurgeMode
| true
, false
| boolean | Night purge mode. |
| | http//ip:port
| HideRoomTemperature
| true
, false
| boolean | Hide room temperature. |
| | http//ip:port
| HideSupplyTemperature
| true
, false
| boolean | Hide supply temperature. |
| | http//ip:port
| HideOutdoorTemperature
| true
, false
| boolean | Hide outdoor temperature. |
| | http//ip:port
| OperationMode
| 1 - Heat
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | http//ip:port
| VentilationMode
| 0 - Lossnay
, 1 - Bypass
, 2 - Auto
| integer | Ventilation mode. |
| | http//ip:port
| SetFanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
| integer | Fan speed. |
| | http//ip:port
| SetTemperature
| 0.0
| float | Room temperature. |
| | http//ip:port
| DefaultCoolingSetTemperature
| 0.0
| float | Default cooling temperature. |
| | http//ip:port
| DefaultHeatingSetTemperature
| 0.0
| float | Default heating temperature. |
MQTT Integration
- Subscribe data as a JSON Object
{"Power": true}
| Direction | Topic | Message | Type |
| --- | --- | --- | --- |
| Publish | Info
, State
| {"Power": true, "SetTemperature": 21.5}
| JSON object. |
| Method | Topic | Key | Value | Type | Description |
| --- | --- | --- | --- | --- | --- |
| Air Conditioner | | | | | |
| Subscribe | Set
| Power
| true
, false
| boolean | Power state. |
| | Set
| HideVaneControls
| true
, false
| boolean | Hide vane controls. |
| | Set
| HideDryModeControl
| true
, false
| boolean | Hide dry mode control. |
| | Set
| ProhibitSetTemperature
| true
, false
| boolean | Lock set temperature. |
| | Set
| ProhibitOperationMode
| true
, false
| boolean | Lock set operating mode. |
| | Set
| ProhibitPower
| true
, false
| boolean | Lock set power. |
| | Set
| OperationMode
| 1 - Heat
, 2 - Dry
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | Set
| FanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
, 5
, 6
| integer | Fan speed. |
| | Set
| VaneHorizontalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 8 - Split
, 12 - Swing
| integer | Vane H mode. |
| | Set
| VaneVerticalDirection
| 0
, 1
, 2
, 3
, 4
, 5
, 7 - Swing
| integer | Vane V mode. |
| | Set
| SetTemperature
| 0.0
| float | Room temperature. |
| | Set
| DefaultCoolingSetTemperature
| 23.0
| float | Default cooling temperature. |
| | Set
| DefaultHeatingSetTemperature
| 21.0
| float | Default heating temperature. |
| Heat Pump | | | | | |
| Subscribe | Set
| Power
| true
, false
| boolean | Power state. |
| | Set
| ForcedHotWaterMode
| true
, false
| boolean | Force hot water. |
| | Set
| EcoHotWater
| true
, false
| boolean | Eco hot water. |
| | Set
| HolidayMode
| true
, false
| boolean | Holiday mode. |
| | Set
| ProhibitZone1
| true
, false
| boolean | Lock control zone 1. |
| | Set
| ProhibitZone2
| true
, false
| boolean | Lock control zone 2. |
| | Set
| ProhibitHotWater
| true
, false
| boolean | Lock control hot water. |
| | Set
| OperationMode
| 0 - Auto
, 1 - Heat
, 2 - Cool
| integer | Operating mode heat pump. |
| | Set
| OperationModeZone1
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 1. |
| | Set
| OperationModeZone2
| 0 - Heat Thermostat
, 1 - Heat Flow
, 2 - Heat Curve
, 3 - Cool Thermostat
, 4 - Cool Flow
, 5 - Flor Dry Up
| integer | Operating mode zone 2. |
| | Set
| SetTemperatureZone1
| 0.0
| float | Temperature zone 1. |
| | Set
| SetTemperatureZone2
| 0.0
| float | Temperature zone 2. |
| | Set
| SetHeatFlowTemperatureZone1
| 0.0
| float | Heat flow temperature zone 1. |
| | Set
| SetHeatFlowTemperatureZone2
| 0.0
| float | Heat flow temperature zone 2. |
| | Set
| SetCoolFlowTemperatureZone1
| 0.0
| float | Cool flow temperature zone 1. |
| | Set
| SetCoolFlowTemperatureZone2
| 0.0
| float | Cool flow temperature zone 2. |
| | Set
| SetTankWaterTemperature
| 0.0
| float | Hot water temperature. |
| Energy Recovery Ventilation | | | | | |
| Subscribe | Set
| Power
| true
, false
| boolean | Power state. |
| | Set
| NightPurgeMode
| true
, false
| boolean | Night purge mode. |
| | Set
| HideRoomTemperature
| true
, false
| boolean | Hide room temperature. |
| | Set
| HideSupplyTemperature
| true
, false
| boolean | Hide supply temperature. |
| | Set
| HideOutdoorTemperature
| true
, false
| boolean | Hide outdoor temperature. |
| | Set
| OperationMode
| 1 - Heat
, 3 - Cool
, 7 - Fan
, 8 - Auto
| integer | Operating mode. |
| | Set
| VentilationMode
| 0 - Lossnay
, 1 - Bypass
, 2 - Auto
| integer | Ventilation mode. |
| | Set
| SetFanSpeed
| 0 - Auto
, 1
, 2
, 3
, 4
| integer | Fan speed. |
| | Set
| SetTemperature
| 0.0
| float | Room temperature. |
| | Set
| DefaultCoolingSetTemperature
| 23.0
| float | Default cooling temperature. |
| | Set
| DefaultHeatingSetTemperature
| 21.0
| float | Default heating temperature. |