npm package discovery and stats viewer.

Discover Tips

  • General search

    [free text search, go nuts!]

  • Package details

    pkg:[package-name]

  • User packages

    @[username]

Sponsor

Optimize Toolset

I’ve always been into building performant and accessible sites, but lately I’ve been taking it extremely seriously. So much so that I’ve been building a tool to help me optimize and monitor the sites that I build to make sure that I’m making an attempt to offer the best experience to those who visit them. If you’re into performant, accessible and SEO friendly sites, you might like it too! You can check it out at Optimize Toolset.

About

Hi, 👋, I’m Ryan Hefner  and I built this site for me, and you! The goal of this site was to provide an easy way for me to check the stats on my npm packages, both for prioritizing issues and updates, and to give me a little kick in the pants to keep up on stuff.

As I was building it, I realized that I was actually using the tool to build the tool, and figured I might as well put this out there and hopefully others will find it to be a fast and useful way to search and browse npm packages as I have.

If you’re interested in other things I’m working on, follow me on Twitter or check out the open source projects I’ve been publishing on GitHub.

I am also working on a Twitter bot for this site to tweet the most popular, newest, random packages from npm. Please follow that account now and it will start sending out packages soon–ish.

Open Software & Tools

This site wouldn’t be possible without the immense generosity and tireless efforts from the people who make contributions to the world and share their work via open source initiatives. Thank you 🙏

© 2024 – Pkg Stats / Ryan Hefner

homebridge-melcloud-control

v3.5.1

Published

Homebridge plugin to control Mitsubishi Air Conditioner, Heat Pump and Energy Recovery Ventilation.

Downloads

2,589

Readme

Homebridge MELCloud Control

verified-by-homebridge npm npm npm GitHub pull requests GitHub issues

Homebridge plugin for Air Conditioner, Heat Pump and Energy Recovery Ventilation Lossnay, manufactured by Mistsubishi and connected to MELCloud.

Package Requirements

| Package | Installation | Role | Required | | --- | --- | --- | --- | | Homebridge v2.0 | Homebridge Wiki | HomeKit Bridge | Required ab v3.0.0 | | Config UI X | Config UI X Wiki | Homebridge Web User Interface | Required ab v3.0.0| | MELCloud | Plug-In Wiki | Homebridge Plug-In | Required |

About The Plugin

  • All devices are detected automatically.
  • Control devices over MELCloud server.
  • Support multiple accounts, buildings, floors, areas.
  • Support temperature display units Celsius/Fahrenheit.
  • Support assing inividual operating mode for Heat/Cool/Auto.
  • Support direct Presets control using extra Buttons, switch it to OFF restore previous device state.
  • Support direct Functions control using extra Buttons, switch it to OFF restore previous device state.
  • Support detect all device states using extra Sensors.
  • Support automations, shortcuts and Siri.
  • Support external integrations, RESTFul, MQTT.
  • Control devices over local network You need use ESP module and Tasmota Control plugin.

Control Mode

  • Air Conditioner:
    • Heater Cooler:
      • Power ON/OFF.
      • Operating mode AUTO/HEAT/COOL/POWER OFF.
      • Temperature HEATING/COOLING/AUTO.
      • Fan speed OFF/1/2/3/4/5/AUTO.
      • Swing mode AUTO/SWING.
      • Physical lock controls LOCK/UNLOCK.
      • Temperature display unit °F/°C.
    • Thermostat:
      • Power ON/OFF.
      • Operating mode POWER OFF/HEAT/COOL/AUTO.
      • Temperature HEATING/COOLING/AUTO.
      • Temperature display unit °F/°C.
      • Assign operating mode for HEAT/AUTO
    • Buttons:
      • For direct device control.
        • Power ON/OFF.
        • Operating mode HEAT/DRY/COOL/FAN/AUTO.
        • Physical lock controls LOCK/UNLOCK.
        • Vane H mode AUTO/1/2/3/4/5/SPLIT/SWING.
        • Vane V mode AUTO/1/2/3/4/5/SWING.
        • Fan speed mode AUTO/1/2/3/4/5.
        • Presets SET/UNSET.
    • Sensors:
      • For automation and notifications.
        • Power ON/OFF.
        • Operating mode HEAT/DRY/COOL/FAN/AUTO.
        • Physical lock controls LOCK/UNLOCK.
        • Vane H mode AUTO/1/2/3/4/5/SPLIT/SWING.
        • Vane V mode AUTO/1/2/3/4/5/SWING.
        • Fan speed mode AUTO/1/2/3/4/5/.
        • Presets ACTIV/UNACTIV.
        • Room temperature.
        • Outdoor temperature.
  • Heat Pump:
    • Heater Cooler:
      • Heat Pump:
        • Power ON/OFF.
        • Operating mode HEAT/COOL.
        • Outdoor temperature GET.
        • Physical lock controls all Zones and Hot Water Tank LOCK/UNLOCK.
        • Temperature display unit °F/°C.
      • Zone 1 and 2:
        • Operating mode heat AUTO/HEAT/COOL - CURVE/HEAT THERMOSTAT/HEAT FLOW.
        • Operating mode cool HEAT/COOL - COOL THERMOSTAT/COOL FLOW.
        • Temperature HEATING/COOLING.
        • Physical lock controls LOCK/UNLOCK.
      • Hot Water Tank:
        • Operating mode AUTO/HEAT - AUTO/HEAT NOW.
        • Temperature SET/GET.
        • Physical lock controls LOCK/UNLOCK.
    • Thermostat:
      • Heat Pump:
        • Power ON/OFF.
        • Operating mode HEAT/COOL.
        • Outdoor temperature GET.
        • Temperature display unit °F/°C.
      • Zone 1 and 2:
        • Operating mode heat HEAT/COOL/AUTO - HEAT THERMOSTAT/HEAT FLOW/CURVE.
        • Operating mode cool HEAT/COOL - COOL THERMOSTAT/COOL FLOW.
        • Temperature HEATING/COOLING.
      • Hot Water Tank:
        • Operating mode HEAT/AUTO - HEAT NOW, AUTO.
        • Temperature SET/GET.
    • Buttons:
      • For direct device control.
        • Power ON/OFF.
        • Operating mode HEAT/COOL/CURVE/HOLIDAY/AUTO HOT WATER/ECO HOT WATER/FORCE HOT WATER.
        • Physical lock controls LOCK/UNLOCK.
        • Presets SET/UNSET.
    • Sensors:
      • For automation and notifications.
        • Power ON/OFF.
        • Operating mode HEAT/COOL/CURVE/HOLIDAY/AUTO HOT WATER/ECO HOT WATER/FORCE HOT WATER.
        • Physical lock controls LOCK/UNLOCK.
        • Presets ACTIV/UNACTIV.
        • Outdoor temperature.
        • Zone 1 temperature.
        • Zone 2 temperature.
        • Water tank temperature.
        • Flow Temperature Zone 1, 2, Hot Water.
        • Return Temperature Zone 1, 2, Hot Water.
  • Energy Recovery Ventilation Lossnay:
    • Heater Cooler:
      • Power ON/OFF.
      • Operating mode AUTO/HEAT/COOL/POWER OFF - AUTO, LOSSNAY, BYPASS, POWER OFF.
      • Fan speed OFF/1/2/3/4/AUTO.
      • Temperature display unit °F/°C.
    • Thermostat:
      • Power ON/OFF.
      • Operating mode POWER OFF/HEAT/COOL/AUTO - POWER OFF, LOSSNAY, BYPASS, AUTO.
      • Temperature display unit °F/°C.
    • Buttons:
      • For direct device control.
        • Power ON/OFF.
        • Operating mode LOSSNAY/BYPASS/AUTO/NIGHT PURGE.
        • Fan speed mode AUTO/1/2/3/4.
        • Presets SET/UNSET.
    • Sensors:
      • For automation and notifications.
        • Power ON/OFF.
        • Operating mode LOSSNAY/BYPASS/AUTO/NIGHT PURGE.
        • Fan speed mode AUTO/1/2/3/4.
        • Presets ACTIV/UNACTIV.
        • Room temperature.
        • Outdoor temperature.
        • Supply temperature.
        • Core maintenance.
        • Filter maintenance.
        • CO2 detected and level.
        • PM2.5 air quality and level.

HOME app current device mode display

  • In AUTO mode, the tile display current state based on current mode:
  • In HEATING mode, th tile display current state as HEATING - orange
  • In COOLING mode, the tile display current state as COOLING - blue
  • In DRY mode, the tile display current state as IDLE - black
  • In FAN mode, the tile display current state as IDLE - black
  • In IDLE mode, the tile display current state as IDLE - black
  • In INACTIVE mode, the tile display current state as INACTIVE - transparent

AUTO Mode

  • Heather/Cooler
    • In this mode we can set heathing threshold and cooling threshold temperature:
    • Target temperature is calculated as a middle value between LO and HI and the rest is calculated internally.
  • Thermostat
    • In this mode we can set only target temperature:
    • Target temperature issend to device and calculated internally:
  • Calculation method in device internally:
    • If the room temperature < Heating Setpoint, the unit will be set to HEAT with a setpoint of 23°C.
    • In HEAT, if the room temperature > Heating Setpoint + 1°C, the unit will be set to FAN.
    • In FAN, if the room temperature > Cooling Setpoint, the unit will be set to COOL with a setpoint of 19°C.
    • In COOL, if the room temperature < Cooling Setpoint - 1°C, the unit will be set to FAN.
    • In FAN, if the room temperature < Heating Setpoint, the unit will be set to HEAT with a setpoint of 23°C.
  • The image shows Heating Setpoint of 19°C and a Cooling Setpoint of 23°C.

Configuration

  • Run this plugin as a Child Bridge (Highly Recommended), this prevent crash Homebridge if plugin crashes.
  • Install and use Homebridge Config UI X to configure this plugin, required for version v3 and above.
  • The sample-config.json can be edited and used as an alternative.

| Key | Description | | --- | --- | | name | Here set the own account name. | | user | Here set the MELCloud username. | | passwd | Here set the MELCloud password. | | language | Here select the MELCloud language. | | ataDevices | Array of ATA devices created automatically after login to MELCloud from plugin config UI. | | ataDevices.id | Read only data, do not change it. | | ataDevices.type | Read only data, do not change it. | | ataDevices.typeString | Read only data, do not change it. | | ataDevices.name | Here You can schange the Accessory Name which is exposed to the Homebridge/HomeKit. | | ataDevices.displayMode | Here select device control mode None/Disabled, Heater/Cooler, Thermostat. | | ataDevices.heatDryFanMode | Here select the operatiing mode for Heat, if this mode is not supported, it will be disabled. | | ataDevices.coolDryFanMode | Here select the operatiing mode for Cool, if this mode is not supported, it will be disabled. | | ataDevices.autoDryFanMode | Here select the operatiing mode for Auto, if this mode is not supported, it will be disabled.. | | ataDevices.temperatureSensor | This enable extra Room temperature sensors to use with automations in HomeKit app. | | ataDevices.temperatureSensorOutdoor | This enable extra Outdoor temperature sensors to use with automations in HomeKit app. | | ataDevices.refreshInterval | Here set the background devices state refresh time in (sec), default 5s. | | ataDevices.presets | Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. | | ataDevices.presets.id | Read only data, do not change it. | | ataDevices.presets.name | Here You can schange the Preset Name which is exposed to the Homebridge/HomeKit. | | ataDevices.presets.displayType | Here select display type in HomeKit, 0 - None/Disabled, 1 - Outlet, 2 - Switch, 3 - Motion Sensor, 4 - Occupancy Sensor, 5 - Contact Sensor. | | buttonsSensors | Array of buttons sensors. | | buttonsSensors.name | Here set Button Name which You want expose to the Homebridge/HomeKit. | | buttonsSensors.mode | Here select button mode, VH - Vane Horizontal, VV - Vane Horizontal. | | buttonsSensors.displayType | Here select display type in HomeKit, 0 - None/Disabled, 1 - Outlet, 2 - Switch, 3 - Motion Sensor, 4 - Occupancy Sensor, 5 - Contact Sensor. | | buttonsSensors.namePrefix | Here enable/disable the accessory name as a prefix for button/sensor name. | | atwDevices | Array of ATA devices created automatically after login to MELCloud from plugin config UI. | | atwDevices.id | Read only data, do not change it. | | atwDevices.type | Read only data, do not change it. | | atwDevices.typeString | Read only data, do not change it. | | atwDevices.name | Here You can schange the Accessory Name which is exposed to the Homebridge/HomeKit. | | atwDevices.displayMode | Here select main control mode None/Disabled, Heater/Cooler, Thermostat. | | atwDevices.temperatureSensor | This enable extra Room temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorFlow | This enable extra Flow temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorReturn | This enable extra Return temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorFlowZone1 | This enable extra Flow Zone 1 temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorReturnZone1 | This enable extra Return Zone 1 temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorFlowWaterTank | This enable extra Flow Water Tank temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorReturnWaterTank | This enable extra Return Water Tank temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorFlowZone2 | This enable extra Flow Zone 2 temperature sensors to use with automations in HomeKit app. | | atwDevices.temperatureSensorReturnZone2 | This enable extra Return Zone 2 temperature sensors to use with automations in HomeKit app. | | atwDevices.refreshInterval | Here set the background devices state refresh time in (sec), default 5s. | | atwDevices.presets | Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. | | atwDevices.presets.id | Read only data, do not change it. | | atwDevices.presets.name | Here You can schange the Preset Name which is exposed to the Homebridge/HomeKit. | | atwDevices.presets.displayType | Here select display type in HomeKit, 0 - None/Disabled, 1 - Outlet, 2 - Switch, 3 - Motion Sensor, 4 - Occupancy Sensor, 5 - Contact Sensor. | | buttonsSensors | Array of buttons sensors. | | buttonsSensors.name | Here set Button Name which You want expose to the Homebridge/HomeKit. | | buttonsSensors.mode | Here select button mode. | | buttonsSensors.displayType | Here select display type in HomeKit, 0 - None/Disabled, 1 - Outlet, 2 - Switch, 3 - Motion Sensor, 4 - Occupancy Sensor, 5 - Contact Sensor. | | buttonsSensors.namePrefix | Here enable/disable the accessory name as a prefix for button/sensor name. | | ervDevices | Array of ATA devices created automatically after login to MELCloud from plugin config UI. | | ervDevices.id | Read only data, do not change it. | | ervDevices.type | Read only data, do not change it. | | ervDevices.typeString | Read only data, do not change it. | | ervDevices.name | Here You can schange the Accessory Name which is exposed to the Homebridge/HomeKit. | | ervDevices.displayMode | Here select main control mode None/Disabled, Heater/Cooler, Thermostat. | | ervDevices.temperatureSensor | This enable extra Room temperature sensors to use with automations in HomeKit app. | | ervDevices.temperatureSensorOutdoor | This enable extra Outdoor temperature sensors to use with automations in HomeKit app. | | ervDevices.temperatureSensorSupply | This enable extra Supply temperature sensors to use with automations in HomeKit app. | | ervDevices.refreshInterval | Here set the background devices state refresh time in (sec), default 5s. | | ervDevices.presets | Array of ATA device Presets created automatically after login to MELCloud from plugin config UI. | | ervDevices.presets.id | Read only data, do not change it. | | ervDevices.presets.name | Here You can schange the Preset Name which is exposed to the Homebridge/HomeKit. | | ervDevices.presets.displayType | Here select display type in HomeKit, 0 - None/Disabled, 1 - Outlet, 2 - Switch, 3 - Motion Sensor, 4 - Occupancy Sensor, 5 - Contact Sensor. | | buttonsSensors | Array of buttons sensors. | | buttonsSensors.name | Here set Button Name which You want expose to the Homebridge/HomeKit. | | buttonsSensors.mode | Here select button mode. | | buttonsSensors.displayType | Here select display type in HomeKit, 0 - None/Disabled, 1 - Outlet, 2 - Switch, 3 - Motion Sensor, 4 - Occupancy Sensor, 5 - Contact Sensor. | | buttonsSensors.namePrefix | Here enable/disable the accessory name as a prefix for button/sensor name. | | refreshInterval | Here set the background account data refresh time in (sec), default 120s. | | enableDebugMode | This enable deep log in homebridge console. | | disableLogInfo | This disable display log values and states on every it change. | | disableLogDeviceInfo | This disable display log device info on plugin start. | | restFul | This is RSTful server. | | restFul.enable | If enabled, RESTful server will start automatically and respond to any path request. | | restFul.port | Here set the listening Port for RESTful server. | | restFul.debug | If enabled, deep log will be present in homebridge console for RESTFul server. | | mqtt | This is MQTT Broker. | | mqtt.enable | If enabled, MQTT Broker will start automatically and publish all awailable PV data. | | mqtt.host | Here set the IP Address or Hostname for MQTT Broker. | | mqtt.port | Here set the Port for MQTT Broker, default 1883. | | mqtt.clientId | Here optional set the Client Id of MQTT Broker. | | mqtt.prefix | Here set the Prefix for Topic or leave empty. | | mqtt.auth | If enabled, MQTT Broker will use authorization credentials. | | mqtt.user | Here set the MQTT Broker user. | | mqtt.passwd | Here set the MQTT Broker password. | | mqtt.debug | If enabled, deep log will be present in homebridge console for MQTT. |

RESTful Integration

  • Port: last 4 numbers of device Id, displayed in HB log during start.
  • POST data as a JSON Object {OperationMode: 8}

| Method | URL | Path | Response | Type | | --- | --- | --- | --- | --- | | GET | http//ip:port | Info, State | {"Power": true, "SetTemperature": 21.5} | JSON object. |

| Method | URL | Key | Value | Type | Description | | --- | --- | --- | --- | --- | --- | | Air Conditioner | | | | | | | POST | http//ip:port | Power | true, false | boolean | Power state. | | | http//ip:port | HideVaneControls | true, false | boolean | Hide vane controls. | | | http//ip:port | HideDryModeControl | true, false | boolean | Hide dry mode control. | | | http//ip:port | ProhibitSetTemperature | true, false | boolean | Lock set temperature. | | | http//ip:port | ProhibitOperationMode | true, false | boolean | Lock set operating mode. | | | http//ip:port | ProhibitPower | true, false | boolean | Lock set power. | | | http//ip:port | OperationMode | 1 - Heat, 2 - Dry, 3 - Cool, 7 - Fan, 8 - Auto | integer | Operating mode. | | | http//ip:port | FanSpeed | 0 - Auto, 1, 2, 3, 4, 5, 6 | integer | Fan speed. | | | http//ip:port | VaneHorizontalDirection | 0, 1, 2, 3, 4, 5, 8 - Split, 12 - Swing | integer | Vane H mode. | | | http//ip:port | VaneVerticalDirection | 0, 1, 2, 3, 4, 5, 7 - Swing | integer | Vane V mode. | | | http//ip:port | SetTemperature | 0.0 | float | Room temperature. | | | http//ip:port | DefaultCoolingSetTemperature | 0.0 | float | Default cooling temperature. | | | http//ip:port | DefaultHeatingSetTemperature | 0.0 | float | Default heating temperature. | | Heat Pump | | | | | | | POST | http//ip:port | Power | true, false | boolean | Power state. | | | http//ip:port | ForcedHotWaterMode | true, false | boolean | Force hot water. | | | http//ip:port | EcoHotWater | true, false | boolean | Eco hot water. | | | http//ip:port | HolidayMode | true, false | boolean | Holiday mode. | | | http//ip:port | ProhibitZone1 | true, false | boolean | Lock control zone 1. | | | http//ip:port | ProhibitZone2 | true, false | boolean | Lock control zone 2. | | | http//ip:port | ProhibitHotWater | true, false | boolean | Lock control hot water. | | | http//ip:port | OperationMode | 0 - Auto, 1 - Heat, 2 - Cool | integer | Operating mode heat pump. | | | http//ip:port | OperationModeZone1 | 0 - Heat Thermostat, 1 - Heat Flow, 2 - Heat Curve, 3 - Cool Thermostat, 4 - Cool Flow, 5 - Flor Dry Up | integer | Operating mode zone 1. | | | http//ip:port | OperationModeZone2 | 0 - Heat Thermostat, 1 - Heat Flow, 2 - Heat Curve, 3 - Cool Thermostat, 4 - Cool Flow, 5 - Flor Dry Up | integer | Operating mode zone 2. | | | http//ip:port | SetTemperatureZone1 | 0.0 | float | Temperature zone 1. | | | http//ip:port | SetTemperatureZone2 | 0.0 | float | Temperature zone 2. | | | http//ip:port | SetHeatFlowTemperatureZone1 | 0.0 | float | Heat flow temperature zone 1. | | | http//ip:port | SetHeatFlowTemperatureZone2 | 0.0 | float | Heat flow temperature zone 2. | | | http//ip:port | SetCoolFlowTemperatureZone1 | 0.0 | float | Cool flow temperature zone 1. | | | http//ip:port | SetCoolFlowTemperatureZone2 | 0.0 | float | Cool flow temperature zone 2. | | | http//ip:port | SetTankWaterTemperature | 0.0 | float | Hot water temperature. | | Energy Recovery Ventilation | | | | | | | POST | http//ip:port | Power | true, false | boolean | Power state. | | | http//ip:port | NightPurgeMode | true, false | boolean | Night purge mode. | | | http//ip:port | HideRoomTemperature | true, false | boolean | Hide room temperature. | | | http//ip:port | HideSupplyTemperature | true, false | boolean | Hide supply temperature. | | | http//ip:port | HideOutdoorTemperature | true, false | boolean | Hide outdoor temperature. | | | http//ip:port | OperationMode | 1 - Heat, 3 - Cool, 7 - Fan, 8 - Auto | integer | Operating mode. | | | http//ip:port | VentilationMode | 0 - Lossnay, 1 - Bypass, 2 - Auto | integer | Ventilation mode. | | | http//ip:port | SetFanSpeed | 0 - Auto, 1, 2, 3, 4 | integer | Fan speed. | | | http//ip:port | SetTemperature | 0.0 | float | Room temperature. | | | http//ip:port | DefaultCoolingSetTemperature | 0.0 | float | Default cooling temperature. | | | http//ip:port | DefaultHeatingSetTemperature | 0.0 | float | Default heating temperature. |

MQTT Integration

  • Subscribe data as a JSON Object {"Power": true}

| Direction | Topic | Message | Type | | --- | --- | --- | --- | | Publish | Info, State | {"Power": true, "SetTemperature": 21.5} | JSON object. |

| Method | Topic | Key | Value | Type | Description | | --- | --- | --- | --- | --- | --- | | Air Conditioner | | | | | | | Subscribe | Set | Power | true, false | boolean | Power state. | | | Set | HideVaneControls | true, false | boolean | Hide vane controls. | | | Set | HideDryModeControl | true, false | boolean | Hide dry mode control. | | | Set | ProhibitSetTemperature | true, false | boolean | Lock set temperature. | | | Set | ProhibitOperationMode | true, false | boolean | Lock set operating mode. | | | Set | ProhibitPower | true, false | boolean | Lock set power. | | | Set | OperationMode | 1 - Heat, 2 - Dry, 3 - Cool, 7 - Fan, 8 - Auto | integer | Operating mode. | | | Set | FanSpeed | 0 - Auto, 1, 2, 3, 4, 5, 6 | integer | Fan speed. | | | Set | VaneHorizontalDirection | 0, 1, 2, 3, 4, 5, 8 - Split, 12 - Swing | integer | Vane H mode. | | | Set | VaneVerticalDirection | 0, 1, 2, 3, 4, 5, 7 - Swing | integer | Vane V mode. | | | Set | SetTemperature | 0.0 | float | Room temperature. | | | Set | DefaultCoolingSetTemperature | 23.0 | float | Default cooling temperature. | | | Set | DefaultHeatingSetTemperature | 21.0 | float | Default heating temperature. | | Heat Pump | | | | | | | Subscribe | Set | Power | true, false | boolean | Power state. | | | Set | ForcedHotWaterMode | true, false | boolean | Force hot water. | | | Set | EcoHotWater | true, false | boolean | Eco hot water. | | | Set | HolidayMode | true, false | boolean | Holiday mode. | | | Set | ProhibitZone1 | true, false | boolean | Lock control zone 1. | | | Set | ProhibitZone2 | true, false | boolean | Lock control zone 2. | | | Set | ProhibitHotWater | true, false | boolean | Lock control hot water. | | | Set | OperationMode | 0 - Auto, 1 - Heat, 2 - Cool | integer | Operating mode heat pump. | | | Set | OperationModeZone1 | 0 - Heat Thermostat, 1 - Heat Flow, 2 - Heat Curve, 3 - Cool Thermostat, 4 - Cool Flow, 5 - Flor Dry Up | integer | Operating mode zone 1. | | | Set | OperationModeZone2 | 0 - Heat Thermostat, 1 - Heat Flow, 2 - Heat Curve, 3 - Cool Thermostat, 4 - Cool Flow, 5 - Flor Dry Up | integer | Operating mode zone 2. | | | Set | SetTemperatureZone1 | 0.0 | float | Temperature zone 1. | | | Set | SetTemperatureZone2 | 0.0 | float | Temperature zone 2. | | | Set | SetHeatFlowTemperatureZone1 | 0.0 | float | Heat flow temperature zone 1. | | | Set | SetHeatFlowTemperatureZone2 | 0.0 | float | Heat flow temperature zone 2. | | | Set | SetCoolFlowTemperatureZone1 | 0.0 | float | Cool flow temperature zone 1. | | | Set | SetCoolFlowTemperatureZone2 | 0.0 | float | Cool flow temperature zone 2. | | | Set | SetTankWaterTemperature | 0.0 | float | Hot water temperature. | | Energy Recovery Ventilation | | | | | | | Subscribe | Set | Power | true, false | boolean | Power state. | | | Set | NightPurgeMode | true, false | boolean | Night purge mode. | | | Set | HideRoomTemperature | true, false | boolean | Hide room temperature. | | | Set | HideSupplyTemperature | true, false | boolean | Hide supply temperature. | | | Set | HideOutdoorTemperature | true, false | boolean | Hide outdoor temperature. | | | Set | OperationMode | 1 - Heat, 3 - Cool, 7 - Fan, 8 - Auto | integer | Operating mode. | | | Set | VentilationMode | 0 - Lossnay, 1 - Bypass, 2 - Auto | integer | Ventilation mode. | | | Set | SetFanSpeed | 0 - Auto, 1, 2, 3, 4 | integer | Fan speed. | | | Set | SetTemperature | 0.0 | float | Room temperature. | | | Set | DefaultCoolingSetTemperature | 23.0 | float | Default cooling temperature. | | | Set | DefaultHeatingSetTemperature | 21.0 | float | Default heating temperature. |