growatt-modbus
v1.0.6
Published
This library natively reads data provided by a growatt inverter. Parsing is based on the documentation "Growatt Inverter Modbus RTU Protocol_II" (V1.05 2018-04-19).
Downloads
20
Readme
Growatt Modbus
This library natively reads data provided by a growatt inverter. Parsing is based on the documentation "Growatt Inverter Modbus RTU Protocol_II" (V1.05 2018-04-19).
Setup
Connect the pin 3 and 4 (modbus A and B) of the growatt COM connector to a modbus to serial converter (e.g. rs485 to TTL converter).
Multiple inverters can be connected to the same converter.
The modbusId can be changed in the configuration menu of the inverter (default: 1).
Installation
yarn add growatt-modbus
Usage
import GrowattClient from 'growatt-modbus';
(async () => {
const growattClient = new GrowattClient({
baudRate: 9600,
device: '/dev/ttyAMA0',
modbusId: 1
});
await growattClient.init();
const data = await growattClient.getData();
})();
Output Example
Tested devices
- [x] Growatt MIC 2500TL-X
- [x] Growatt MIN 4200TL-XE
Contributing