fritzapi
v0.13.0
Published
Home automation node API for Fritz!Box, Fritz!DECT and FRITZ!Powerline devices
Downloads
513
Maintainers
Readme
fritzapi
Home automation node API for Fritz!Box, Fritz!DECT and FRITZ!Powerline devices.
homebridge-fritz and pimatic-fritz are built on fritzapi.
Functions
General functions
- Get the Fritz!OS version
getOSVersion
- Get the session ID
getSessionID
- Get device list as XML
getDeviceListInfos
>Fritz!OS 6.10 - Get device list
getDeviceList
>Fritz!OS 6.10 - Get device list with filter criteria applied
getDeviceListFiltered
>Fritz!OS 6.10 - Get device
getDevice
>Fritz!OS 6.10 - Get temperature
getTemperature
- polyfill - Get presence
getPresence
- polyfill - Get template list as XML
getTemplateListInfos
>Fritz!OS 7.0 - Get template list
getTemplateList
>Fritz!OS 7.0 - Get template list
applyTemplate
>Fritz!OS 7.0
Note
getTemperature
works for DECT repeaters but is not available on the FRITZ!Powerline 546E WLAN set and will always return NaN
.
While getTemperature
works for outlets, it is not available for (outlet) groups that can be created through the Fritz!Box user interface.
getDeviceListInfos
was named getDeviceListInfo
in earlier versions. For consistency with the official Fritz!Box API the name has been changed. The getDeviceListInfo
name is deprecated and will be removed in a future release.
In general, use of getDeviceListInfos
is discouraged as the equivalent getDeviceList
function which returns an object interface instead of XML is easier to use.
Fritz!DECT 200 and 210 outlet functions (includes FRITZ!Powerline 546E)
- Get list
getSwitchList
- Get state
getSwitchState
- Set on
setSwitchOn
- Set off
setSwitchOff
- Toggle
setSwitchToggle
- Get power
getSwitchPower
- Get energy
getSwitchEnergy
- Get presence status
getSwitchPresence
- Get name
getSwitchName
- Get basic device stats as XML
getBasicDeviceStats
>Fritz!OS 7.0
For controlling AVM Fritz!DECT 200 devices the actuator identification number (AIN) is needed. The AIN can be obtained using getSwitchList
which returns a list of AINs or the more general getDeviceList
function which returns a verbose device list structure as JSON.
Fritz!DECT 100 functions
The Fritz!DECT 100 DECT repeater AIN does only appear in the getDeviceList
output. It supports retrieving the repeater's temperature.
Fritz!DECT 300, 301 and CometDECT thermostat functions
Thermostat functions are only available as of Fritz!OS 6.36
- Get list
getThermostatList
- polyfill - Set target temperature
setTempTarget
, supports 'ON'/'OFF' to enable/disable thermostat - Get target temperature
getTempTarget
- Get comfort temperature
getTempComfort
- Get night temperature
getTempNight
- Get battery charge
getBatteryCharge
(uses UI scraping, may be unstable) - Get window open
getWindowOpen
(uses UI scraping, may be unstable)
Fritz!DECT 500 and Telekom bulb functions
Bulb functions are only available as of Fritz!OS 7.20
- Get List of all bulbs
getBulbList
- Get List of all bulbs supporting colors
getColorBulbList
- Switch bulb on/off or toggle it
setSimpleOnOff
- Dimm a bulb
setLevel
, 0 - 255 - Dimm a bulb
setLevelPercentage
, 0 - 100 - Set the color and saturation
setColor
, see note 1 - Set the color temperature
setColorTemperature
, see note 2
Note 1
The color api calls of the FritzBox accept only a predefined set of values.
To get easy access to the predefined values fritzapi accepts the following values as the color:red, orange, yellow, lime, green, turquoise, cyan, lightblue, blue, purple, magenta, pink
The saturation can be 0, 1 or 2
to select one of the predefined saturation values for the color.
Note 2
The color temperature api calls of the FritzBox accept only a predefined set of values.
Valid values are 2700, 3000, 3400,3800, 4200, 4700, 5300, 5900 and 6500
.
Other values are adjusted by fritzapi to one of the above values.
WLAN functions
- Get the guest wlan settings
getGuestWlan
- Set the guest wlan
setGuestWlan
Note
getGuestWlan
returns a structure containing all wifi settings found in the Fritz!Box UI. The setGuestWlan
function accepts either a settings structure such as this or a single boolean value.
All functions have been tested on Fritz!OS 6.20/6.36/6.51 using the Fritz!Box 7390 and on Fritz!OS 6.50 on Fritz!Box 6490. The WLAN functions may be less stable.
Installation
npm install fritzapi
Usage
Object-oriented interface
The object-oriented interface is the recommended way of using fritzapi.
Get the list of switch AINs using a customer Fritz!Box address:
var Fritz = require('fritzapi').Fritz;
var f = new Fritz("user", "password", "http://192.168.178.1");
f.getSwitchList().then(function(ains){
console.log(f.getSID());
console.log(ains);
});
Functional interface
Get the session ID using default Fritz!Box address (http://fritz.box):
var fritz = require('fritzapi');
fritz.getSessionID("user", "password").then(function(sid) {
console.log(sid);
});
Get the list of switch AINs using a custom Fritz!Box address with self-signed certificate:
fritz.getSessionID("user", "password", {
url: "192.168.178.1",
strictSSL: false // workaround DEPTH_ZERO_SELF_SIGNED_CERT SSL error
}).then(function(sid) {
console.log(sid);
// note that the options/url need be carries through every single api call
fritz.getSwitchList(sid, options).then(function(ains){
console.log(ains);
});
});
Note The functional interface may be deprecated in a future version of the library.
Device details
Below is the output of getDeviceList
for reference.
The list was produced for various Fritz devices I've had around. It might have changed in the meantime depending on device firmware or Fritz HTTP API version.
These definitions remain cached by the Fritz!Box even if the device is no longer connected. The device presence is indicated by the present
attribute.
Powerline
{ identifier: '34:31:C4:DB:F6:C7',
id: '20000',
functionbitmask: '640',
fwversion: '06.20',
manufacturer: 'AVM',
productname: 'FRITZ!Powerline 546E',
present: '0',
name: 'FRITZ!Powerline 546E',
switch: { state: '', mode: '', lock: '' },
powermeter: { power: '', energy: '' } }
Outlets
{ identifier: '087610103568',
id: '17',
functionbitmask: '35712',
fwversion: '04.16',
manufacturer: 'AVM',
productname: 'FRITZ!DECT 200',
present: '1',
name: 'FRITZ!DECT 200 #1',
switch: { state: '', mode: '', lock: '', devicelock : '' },
simpleonoff { state: '' },
powermeter: { voltage: '', power: '', energy: '' },
temperature: { celsius: '', offset: '' }
}
{ identifier: '116570031825',
id: '18',
functionbitmask: '640',
fwversion: '03.67',
manufacturer: 'AVM',
productname: 'FRITZ!DECT 210',
present: '0',
name: 'FRITZ!DECT 210 #3',
switch: { state: '', mode: '', lock: '' },
powermeter: { power: '', energy: '' } }
DECT Repeater
{ identifier: '116570002527',
id: '20',
functionbitmask: '1024',
fwversion: '03.64',
manufacturer: 'AVM',
productname: 'FRITZ!DECT Repeater 100',
present: '0',
name: 'FRITZ!DECT Rep 100 #5' }
Thermostats
{ identifier: '109710195784',
id: '17',
functionbitmask: '320',
fwversion: '03.54',
manufacturer: 'AVM',
productname: 'Comet DECT',
present: '1',
txbusy: '0'
name: 'Comet DECT',
battery: '90'
batterylow: '0'
temperature: { celsius: '', offset: '' },
hkr: { tist: '49', tsoll: '253', absenk: '32', komfort: '42', lock: '1', devicelock: '1', errorcode: '0',
windowopenactiv: '0', windowopenactiveendtime: '0', boostactive: '0', boostactiveendtime: '0',
battery: '90', batterylow: '0', summeractive: '1', holidayactive: '0',
nextchange: { endperiod: '1598907600', tchange: '32' }} }
HANFUN
As of Fritz!OS 7 the HANFUN devices have their own bitmask 1
:
{ identifier: '119340326786',
id: '406',
functionbitmask: '1',
fwversion: '00.00',
manufacturer: '0x0feb',
productname: 'HAN-FUN',
present: '1',
name: 'HAN-FUN #1' }
HANFUN functions are accessible as "HANFUN unit" devices. Bitmask consists of HANFUN unit (bit 13) plus actual function (in this case ALARM, bit 3):
{ identifier: '119340326786-1',
id: '2000',
functionbitmask: '8208',
fwversion: '0.0',
manufacturer: '0x0feb',
productname: 'HAN-FUN',
present: '1',
name: 'no name',
etsiunitinfo: { etsideviceid: '406', unittype: '514', interfaces: '256' },
alert: { state: '1' } }
or a color bulb:
{ identifier: '127010028190-1',
id: '2000',
functionbitmask: '237572',
fwversion: '0.0',
manufacturer: '0x319d',
productname: 'HAN-FUN',
present: '0',
txbusy: '0'
name: 'Bulb 1',
simpleonoff { state: '1' },
levelcontrol: { level: '255', levelpercentage: '100' },
colorcontrol: { supported_modes: '5', current_mode: '1', hue: '35', saturation: '214', temperature: '' },
etsiunitinfo: { etsideviceid: '406', unittype: '278', interfaces: '512,514,513' } }
AHA HTTP Interface Documentation
http://avm.de/fileadmin/user_upload/Global/Service/Schnittstellen/AHA-HTTP-Interface.pdf
Acknowledgements
Thanks to:
- AVM for providing free test devices and the AHA-HTTP interface document
- EUROtronic Technology GmbH for providing free CometDECT thermostat sample
- nischelwitzer for the basic js implementation (https://github.com/nischelwitzer/smartfritz)
- steffen.timm for the basic communication function
- thk4711 for the FRITZ!DECT 200 codes