npm package discovery and stats viewer.

Discover Tips

  • General search

    [free text search, go nuts!]

  • Package details

    pkg:[package-name]

  • User packages

    @[username]

Sponsor

Optimize Toolset

I’ve always been into building performant and accessible sites, but lately I’ve been taking it extremely seriously. So much so that I’ve been building a tool to help me optimize and monitor the sites that I build to make sure that I’m making an attempt to offer the best experience to those who visit them. If you’re into performant, accessible and SEO friendly sites, you might like it too! You can check it out at Optimize Toolset.

About

Hi, 👋, I’m Ryan Hefner  and I built this site for me, and you! The goal of this site was to provide an easy way for me to check the stats on my npm packages, both for prioritizing issues and updates, and to give me a little kick in the pants to keep up on stuff.

As I was building it, I realized that I was actually using the tool to build the tool, and figured I might as well put this out there and hopefully others will find it to be a fast and useful way to search and browse npm packages as I have.

If you’re interested in other things I’m working on, follow me on Twitter or check out the open source projects I’ve been publishing on GitHub.

I am also working on a Twitter bot for this site to tweet the most popular, newest, random packages from npm. Please follow that account now and it will start sending out packages soon–ish.

Open Software & Tools

This site wouldn’t be possible without the immense generosity and tireless efforts from the people who make contributions to the world and share their work via open source initiatives. Thank you 🙏

© 2024 – Pkg Stats / Ryan Hefner

ecg-data-processor

v1.2.0

Published

A JavaScript library for processing and analyzing ECG data, including noise filtering, PQRST wave detection, and clinical indicator calculations.

Downloads

30

Readme

ECG Data Processor

ECG Data Processor is a JavaScript library designed for analyzing and processing ECG data. It provides tools for filtering noise, detecting key PQRST waveforms, and calculating clinical indicators such as PR interval, QRS duration, and heart rate.

Features

  • Noise filtering (high-pass, low-pass, and notch filters)
  • Detection and extraction of PQRST waves
  • Calculation of PR interval, QRS duration, QT interval, and heart rate
  • Real-time and batch ECG signal processing
  • Configurable for different sampling rates and heart rates

Installation

Install the library using npm:

npm install ecg-data-processor

Usage

Here’s a basic example of using the library:

const ecgProcessor = require('ecg-data-processor');

const ecgData = [ 0.05, 0.1,  0.15, ...];  // ECG data points [time (ms), voltage]
const processedData = ecgProcessor.process(ecgData);

console.log(processedData);

Example

The following example demonstrates how to use the library to process ECG data:

  1. Prepare your ECG voltage(usually between -1.5mV ~ 1.5mV) data in a text file (e.g., ecg.txt), where each line represents a single data point (a numeric value). For example:
0.061165
0.075489
0.089244
0.100792
0.10895099999999999
0.11308700000000001
0.11303
0.109092
...
  1. Process the data using the library in your code:
import { process } from 'ecg-data-process';
import fs from 'fs';
import path from 'path';

// Read ECG data from a file
const filePath = path.resolve('test/ecg.txt');
const fileContent = fs.readFileSync(filePath, 'utf-8');

// Parse ECG data
const ecgData = fileContent.split('\n').map(line => {
    return line.trim() * 1;
});

// Process the data with a specific frequency (e.g., 511.547 Hz)
const processedData = process(ecgData, 511.547);

// Get the result
const processedResult = processedData.getResult();

console.log(processedResult.summary);
console.log(processedResult.segments[0].beats[0]);

Output

The processed result will provide the following summary:

{
  "hr": 81,
  "st": 0.0881,
  "pr": 143.68,
  "qrs": 137.17
}
  • HR: Heart Rate (beats per minute)
  • ST: ST segment (seconds)
  • PR: PR interval (milliseconds)
  • QRS: QRS duration (milliseconds)

The processed result will also provide the following beats:

{
  "valid": true,
  "start_time": 263.9053693990972,
  "end_time": 840.5874729008282,
  "p": {
    "start_time": 322.55100704334103,
    "end_time": 351.87382586546295,
    "peak_time": 342.09955292475564,
    "peak_voltage": 0.061911
  },
  "q": {
    "start_time": 400.7451905689995,
    "end_time": 459.3908282132433,
    "peak_time": 449.616555272536,
    "peak_voltage": -0.08918899999999999
  },
  "r": {
    "start_time": 459.3908282132433,
    "end_time": 508.26219291677984,
    "peak_time": 488.7136470353652,
    "peak_voltage": 0.25517439999999997
  },
  "s": {
    "start_time": 508.26219291677984,
    "end_time": 566.9078305610236,
    "peak_time": 537.5850117389017,
    "peak_voltage": -0.1733224
  },
  "t": {
    "start_time": 635.3277411459748,
    "end_time": 762.3932893751697,
    "peak_time": 723.2961976123405,
    "peak_voltage": 0.170142
  }
}

More Usage

For additional usage examples, you can refer to the test code in the /test directory.

Options Description

all options are optional, you can use the default values if you don't want to change them.

  • debug: boolean (default: false)

    • Enables or disables debug mode. When set to true, additional log information will be output for troubleshooting or analysis purposes.
  • aggregation: number (default: Math.floor(frequency / 100))

    • The number of data points to aggregate, which helps block high-frequency noise in the ECG data. A higher value means more aggregation, reducing noise but potentially losing fine details. The default value is based on the sampling frequency of the data.
  • rPeakSlopeThreshold: number (default: 0.05)

    • The threshold for detecting the slope of R-peaks in the ECG waveform. Lower values may result in more sensitive peak detection, while higher values will detect fewer peaks.
  • rPeakMinDistance: number (default: 30)

    • The minimum distance (in data points) between consecutive R-peaks. This prevents false R-peak detection when two peaks are too close to each other.
  • smoothWindowSize: number (default: 5)

    • The window size for the smoothing function applied to the ECG data. A larger window results in more smoothing, but may reduce the clarity of certain waveforms.
  • baselineFilter: enum (default: LOWPASS)

    • The filter used to remove baseline wander from the ECG signal. It can take the following values:
      • LOWPASS: A low-pass filter to smooth out high-frequency noise (default).
      • MEDIAN: A median filter for removing noise while preserving sharp edges.
      • MEAN: A mean filter for averaging nearby values.

    Users can select a filter by importing the available filters:

    import { filters } from 'ecg-data-process';
    const filter = filters.LOWPASS; // Example
  • baselineFilterOptions: object

    • The configuration options for the selected baseline filter:
      • alpha: number (default: 0.05)
        • Used when the LOWPASS filter is selected. It controls the smoothing factor, with lower values providing smoother output by giving more weight to previous data points.
      • windowSize: number (default: 20)
        • Used when the MEDIAN or MEAN filters are selected. It determines the number of data points considered for filtering.
  • throughMinDistance: number (default: 10)

    • The minimum distance (in data points) between consecutive troughs in the ECG waveform. This ensures that noise or small variations do not cause false detection of troughs.
  • useDirectData: boolean (default: false)
    If true, the process function will treat ecgData as [[time_in_seconds/frequency, voltage], ...] and will not aggregate any data.

  • minPWaveHeight: number (default: 0)
    This option sets the minimum height threshold for detecting P-waves in the ECG signal. It is used to filter out noise and prevent false identification of P-waves that may be caused by low-amplitude noise. If the detected P-wave's amplitude is below this threshold, it will be ignored in the analysis.

  • minTWaveHeight: number (default: 0.1)
    This option sets the minimum height threshold for detecting T-waves in the ECG signal. Similar to the minPWaveHeight, it is used to filter out noise and prevent false identification of T-waves with low amplitude. Only T-waves that meet or exceed this height will be considered valid in the analysis.

Changelog

[1.2.0] - 2024-10-02

Major Changes

  • Rewrote Algorithm for QRS Complex Detection:

    • Improved accuracy in detecting the QRS complex with enhanced accuracy, especially in noisy datasets.
  • Added New Options for Wave Identification:

    • minPWaveHeight: New option introduced to filter out noise and improve the accuracy of P-wave identification by setting a minimum height threshold.
    • minTWaveHeight: New option introduced to filter out noise and improve the accuracy of T-wave identification by setting a minimum height threshold.

Bug Fixes

  • Fixed various bugs related to wave detection and noise filtering.

[1.1.6] - 2024-09-18

  • Improve ST Voltage accuracy.

[1.1.4] - 2024-09-17

  • Improve algorithm accuracy.

[1.1.3] - 2024-09-16

  • Bug fix: Potential array index out of bounds error.

[1.1.2] - 2024-09-16

  • improve the documentation.

[1.1.0] - 2024-09-16

Added

  • useDirectData option: When set to true, the process function uses the ECG data directly as [[time_in_seconds/frequency, voltage], ...] without aggregation.
  • Added test file use_direct_data.test.mjs to validate the functionality of the useDirectData option.
  • Fixed some bugs.

[1.0.0] - 2024-09-15

Added

  • Initial release of the ECG Data Processor library.
  • Added support for ECG data processing, including:
    • Noise filtering.
    • PQRST wave detection.
    • Clinical indicator calculations (heart rate, PR, QRS, etc.).
  • Introduced several configuration options:
    • debug: Toggle debug mode.
    • aggregation: Controls data aggregation and noise blocking.
    • rPeakSlopeThreshold: Threshold for R peak detection.
    • rPeakMinDistance: Minimum distance between R peaks.
    • smoothWindowSize: Window size for data smoothing.
    • baselineFilter: Enum for baseline filtering methods (LOWPASS, MEDIAN, MEAN).
    • baselineFilterOptions: Options for baseline filtering, including alpha and windowSize.
    • throughMinDistance: Minimum distance between through points.

Tests

  • Added test cases in /test/default_with_noise.test.js for verifying ECG data processing.

License

This project is licensed under the MIT License - see the LICENSE file for details.

Let me know if you'd like to modify any sections!