ecg-data-processor
v1.2.0
Published
A JavaScript library for processing and analyzing ECG data, including noise filtering, PQRST wave detection, and clinical indicator calculations.
Downloads
30
Maintainers
Readme
ECG Data Processor
ECG Data Processor is a JavaScript library designed for analyzing and processing ECG data. It provides tools for filtering noise, detecting key PQRST waveforms, and calculating clinical indicators such as PR interval, QRS duration, and heart rate.
Features
- Noise filtering (high-pass, low-pass, and notch filters)
- Detection and extraction of PQRST waves
- Calculation of PR interval, QRS duration, QT interval, and heart rate
- Real-time and batch ECG signal processing
- Configurable for different sampling rates and heart rates
Installation
Install the library using npm:
npm install ecg-data-processor
Usage
Here’s a basic example of using the library:
const ecgProcessor = require('ecg-data-processor');
const ecgData = [ 0.05, 0.1, 0.15, ...]; // ECG data points [time (ms), voltage]
const processedData = ecgProcessor.process(ecgData);
console.log(processedData);
Example
The following example demonstrates how to use the library to process ECG data:
- Prepare your ECG voltage(usually between -1.5mV ~ 1.5mV) data in a text file (e.g., ecg.txt), where each line represents a single data point (a numeric value). For example:
0.061165
0.075489
0.089244
0.100792
0.10895099999999999
0.11308700000000001
0.11303
0.109092
...
- Process the data using the library in your code:
import { process } from 'ecg-data-process';
import fs from 'fs';
import path from 'path';
// Read ECG data from a file
const filePath = path.resolve('test/ecg.txt');
const fileContent = fs.readFileSync(filePath, 'utf-8');
// Parse ECG data
const ecgData = fileContent.split('\n').map(line => {
return line.trim() * 1;
});
// Process the data with a specific frequency (e.g., 511.547 Hz)
const processedData = process(ecgData, 511.547);
// Get the result
const processedResult = processedData.getResult();
console.log(processedResult.summary);
console.log(processedResult.segments[0].beats[0]);
Output
The processed result will provide the following summary:
{
"hr": 81,
"st": 0.0881,
"pr": 143.68,
"qrs": 137.17
}
- HR: Heart Rate (beats per minute)
- ST: ST segment (seconds)
- PR: PR interval (milliseconds)
- QRS: QRS duration (milliseconds)
The processed result will also provide the following beats:
{
"valid": true,
"start_time": 263.9053693990972,
"end_time": 840.5874729008282,
"p": {
"start_time": 322.55100704334103,
"end_time": 351.87382586546295,
"peak_time": 342.09955292475564,
"peak_voltage": 0.061911
},
"q": {
"start_time": 400.7451905689995,
"end_time": 459.3908282132433,
"peak_time": 449.616555272536,
"peak_voltage": -0.08918899999999999
},
"r": {
"start_time": 459.3908282132433,
"end_time": 508.26219291677984,
"peak_time": 488.7136470353652,
"peak_voltage": 0.25517439999999997
},
"s": {
"start_time": 508.26219291677984,
"end_time": 566.9078305610236,
"peak_time": 537.5850117389017,
"peak_voltage": -0.1733224
},
"t": {
"start_time": 635.3277411459748,
"end_time": 762.3932893751697,
"peak_time": 723.2961976123405,
"peak_voltage": 0.170142
}
}
More Usage
For additional usage examples, you can refer to the test code in the /test
directory.
Options Description
all options are optional, you can use the default values if you don't want to change them.
debug:
boolean
(default:false
)- Enables or disables debug mode. When set to
true
, additional log information will be output for troubleshooting or analysis purposes.
- Enables or disables debug mode. When set to
aggregation:
number
(default:Math.floor(frequency / 100)
)- The number of data points to aggregate, which helps block high-frequency noise in the ECG data. A higher value means more aggregation, reducing noise but potentially losing fine details. The default value is based on the sampling frequency of the data.
rPeakSlopeThreshold:
number
(default:0.05
)- The threshold for detecting the slope of R-peaks in the ECG waveform. Lower values may result in more sensitive peak detection, while higher values will detect fewer peaks.
rPeakMinDistance:
number
(default:30
)- The minimum distance (in data points) between consecutive R-peaks. This prevents false R-peak detection when two peaks are too close to each other.
smoothWindowSize:
number
(default:5
)- The window size for the smoothing function applied to the ECG data. A larger window results in more smoothing, but may reduce the clarity of certain waveforms.
baselineFilter:
enum
(default:LOWPASS
)- The filter used to remove baseline wander from the ECG signal. It can take the following values:
LOWPASS
: A low-pass filter to smooth out high-frequency noise (default).MEDIAN
: A median filter for removing noise while preserving sharp edges.MEAN
: A mean filter for averaging nearby values.
Users can select a filter by importing the available filters:
import { filters } from 'ecg-data-process'; const filter = filters.LOWPASS; // Example
- The filter used to remove baseline wander from the ECG signal. It can take the following values:
baselineFilterOptions:
object
- The configuration options for the selected baseline filter:
- alpha:
number
(default:0.05
)- Used when the
LOWPASS
filter is selected. It controls the smoothing factor, with lower values providing smoother output by giving more weight to previous data points.
- Used when the
- windowSize:
number
(default:20
)- Used when the
MEDIAN
orMEAN
filters are selected. It determines the number of data points considered for filtering.
- Used when the
- alpha:
- The configuration options for the selected baseline filter:
throughMinDistance:
number
(default:10
)- The minimum distance (in data points) between consecutive troughs in the ECG waveform. This ensures that noise or small variations do not cause false detection of troughs.
useDirectData:
boolean
(default:false
)
Iftrue
, theprocess
function will treatecgData
as[[time_in_seconds/frequency, voltage], ...]
and will not aggregate any data.minPWaveHeight:
number
(default:0
)
This option sets the minimum height threshold for detecting P-waves in the ECG signal. It is used to filter out noise and prevent false identification of P-waves that may be caused by low-amplitude noise. If the detected P-wave's amplitude is below this threshold, it will be ignored in the analysis.minTWaveHeight:
number
(default:0.1
)
This option sets the minimum height threshold for detecting T-waves in the ECG signal. Similar to theminPWaveHeight
, it is used to filter out noise and prevent false identification of T-waves with low amplitude. Only T-waves that meet or exceed this height will be considered valid in the analysis.
Changelog
[1.2.0] - 2024-10-02
Major Changes
Rewrote Algorithm for QRS Complex Detection:
- Improved accuracy in detecting the QRS complex with enhanced accuracy, especially in noisy datasets.
Added New Options for Wave Identification:
minPWaveHeight
: New option introduced to filter out noise and improve the accuracy of P-wave identification by setting a minimum height threshold.minTWaveHeight
: New option introduced to filter out noise and improve the accuracy of T-wave identification by setting a minimum height threshold.
Bug Fixes
- Fixed various bugs related to wave detection and noise filtering.
[1.1.6] - 2024-09-18
- Improve ST Voltage accuracy.
[1.1.4] - 2024-09-17
- Improve algorithm accuracy.
[1.1.3] - 2024-09-16
- Bug fix: Potential array index out of bounds error.
[1.1.2] - 2024-09-16
- improve the documentation.
[1.1.0] - 2024-09-16
Added
- useDirectData option: When set to
true
, theprocess
function uses the ECG data directly as[[time_in_seconds/frequency, voltage], ...]
without aggregation. - Added test file
use_direct_data.test.mjs
to validate the functionality of theuseDirectData
option. - Fixed some bugs.
[1.0.0] - 2024-09-15
Added
- Initial release of the ECG Data Processor library.
- Added support for ECG data processing, including:
- Noise filtering.
- PQRST wave detection.
- Clinical indicator calculations (heart rate, PR, QRS, etc.).
- Introduced several configuration options:
- debug: Toggle debug mode.
- aggregation: Controls data aggregation and noise blocking.
- rPeakSlopeThreshold: Threshold for R peak detection.
- rPeakMinDistance: Minimum distance between R peaks.
- smoothWindowSize: Window size for data smoothing.
- baselineFilter: Enum for baseline filtering methods (
LOWPASS
,MEDIAN
,MEAN
). - baselineFilterOptions: Options for baseline filtering, including
alpha
andwindowSize
. - throughMinDistance: Minimum distance between through points.
Tests
- Added test cases in
/test/default_with_noise.test.js
for verifying ECG data processing.
License
This project is licensed under the MIT License - see the LICENSE file for details.