climate-si7020
v0.1.1
Published
The library for using the Climate si7020 module for Tessel. Get temperature and humidity.
Downloads
45
Keywords
Readme
Climate
Driver for the climate-si7020 Tessel climate module (Si7020).
Not to be confused with the climate-si7005 Tessel climate module
Hardware overview/setup
The module may come with a protective white cover over the sensor, as shown in the image below. This cover is permeable and does not need to be removed before use. If the protective cover is removed, avoid touching, poking, or dirtying the exposed silicon die.
##Installation
npm install climate-si7020
##Example
var tessel = require('tessel');
var climatelib = require('climate-si7020');
var climate = climatelib.use(tessel.port['A']);
climate.on('ready', function(){
setInterval(function(){
climate.readHumidity(function(err, humid){
climate.readTemperature('f', function(err, temp){
console.log('Degrees:', temp.toFixed(4) + 'F', 'Humidity:', humid.toFixed(4) + '%RH');
});
});
}, 1000);
});
climate.on('error', function(err) {
console.log('error connecting module', err);
});
Methods
climate
.connect(interface[, csn]) Takes in the port bank that the module is connected to. Returns the Climate object.climate
.readTemperature([format,] callback(err, temp)) Returns the temperature in degrees Celcius or Fahrenheit.climate
.readHumidity(callback(err, humidity)) Returns the relative humidity.climate
.setHeater(bool[, callback(err)]) Sets the HEAT config register. The heater evaporates off any moisture that may condense on the sensor in high humidty environments. Enabling the heater will increases the accuracy of humidity measurements but will interfere with temperature measurement. According to section 5.1.4 of the datasheet
Turning on the heater will reduce the tendency of the humidity sensor to accumulate an offset due to “memory” of sustained high humidity conditions. When the heater is enabled, the reading of the on-chip temperature sensor will be affected (increased).
climate
.setFastMeasure(bool[, callback(err)]) Sets the FAST config register. According to section 5.1.3 of the datasheet
Fast mode reduces the total power consumed during a conversion or the average power consumed by the Si7005 when making periodic conversions. It also reduces the resolution of the measurements.
| Normal | Fast
--- | --- | --- converstion time | 35ms | 18ms temp resolution | 14 bit | 13 bit humidity resolution | 12 bit | 11 bit
References
License
MIT/Apache, your pick