@spectraautomation/node-red-urbancontroller-dio
v1.3.3
Published
Node-RED module for controlling the digital input / output port of the Urban Controller by Spectra GmbH & Co. KG
Downloads
9
Readme
node-red-urbancontroller-dio
Node-RED module for controlling the digital input / output port of the Urban Controller by Spectra GmbH & Co. KG
UC1
DIO Pin Assignment
| Pin | Function | |-----|----------| | 1 | + 9-30V | | 2 | DI0 | | 3 | DI1 | | 4 | DI2 | | 5 | DI3 | | 6 | DO0 | | 7 | DO1 | | 8 | DO2 | | 9 | DO3 | | 10 | GND |
UC2
DIO Pin Assignment
| Pin | DI Function | DO Function | |-----|-------------|-------------| | 1 | + 9-30V | + 9-30V | | 2 | DI0 | DO0 | | 3 | DI1 | DO1 | | 4 | DI2 | DO2 | | 5 | DI3 | DO3 | | 6 | DI4 | DO4 | | 7 | DI5 | DO5 | | 8 | DI6 | DO6 | | 9 | DI7 | DO7 | | 10 | GND | GND |
UC3
DIO Pin Assignment
| Pin | DI Function | DO Function | |-----|-------------|-------------| | 1 | + 9-30V | + 9-30V | | 2 | DI0 | DO0 | | 3 | DI1 | DO1 | | 4 | DI2 | DO2 | | 5 | DI3 | DO3 | | 6 | DI4 | DO4 | | 7 | DI5 | DO5 | | 8 | DI6 | DO6 | | 9 | DI7 | DO7 | | 10 | GND | GND |
Voltage levels
- DIO supply voltage: 0-30 VDC
- Maximal current: 580mA @ 9V - 3A @ 20V
- Overall current: 6A
Voltage level logic 0:
Voltage level logic 1: