Timer 0 (TMR0)
Overview
The Timer0 module operates as a synchronous/asynchronous 8/16-bit timer/counter. It features a programmable period (8-bit mode only), and selectable clock sources, prescalers, and interrupts.
Changelog
All notable changes to this project will be documented in this file.
[4.0.13] - 2024-02-14
New Features
- CC8SCRIP-19504 :- Internal Improvements
Improvements
- CC8SCRIP-7838 :- Q83 TMR0 period register does not indicate units of time
[4.0.12] - 2023-11-14
Bug Fixes
- CC8SCRIP-17919 :- Custom name issue with the MCC generated code for Timers
- CC8SCRIP-13733 :- Fixed ticker factor component as alphanumeric value for TMR0
- CC8SCRIP-12534 :- Fixed TMR0 callback function rate units
- CC8SCRIP-9069 :- Added milliseconds (ms) and microseconds (us) units to display for Timer0 Actual Period
[4.0.11] - 2022-11-24
Bug Fixes
- CC8SCRIP-9181 :- Incorrect initialization for TMR_INTERFACE structure.
- CC8SCRIP-9047 :- Override default timer clock source to HFINTOSC.
- CC8SCRIP-4031 :- Severe notification is getting displayed when multiple timers are loaded.